T. L. Allinger and J. R. Engsberg, A method to determine the range of motion of the ankle joint complex, in vivo, Journal of Biomechanics, vol.26, issue.1
DOI : 10.1016/0021-9290(93)90614-K

D. Amarantini and L. Martin, A method to combine numerical optimization and EMG data for the estimation of joint moments under dynamic conditions, Journal of Biomechanics, vol.37, issue.9, pp.1393-1404, 2004.
DOI : 10.1016/j.jbiomech.2003.12.020

T. S. Buchanan, Evidence that maximum muscle stress is not a constant: differences in specific tension in elbow flexors and extensors, Medical Engineering & Physics, vol.17, issue.7, pp.529-536, 1995.
DOI : 10.1016/1350-4533(95)00005-8

T. S. Buchanan, D. G. Lloyd, K. Manal, and T. F. Besier, Neuromusculoskeletal Modeling: Estimation of Muscle Forces and Joint Moments and Movements from Measurements of Neural Command, Journal of Applied Biomechanics, vol.20, issue.4, pp.367-395, 2004.
DOI : 10.1123/jab.20.4.367

J. M. Topp and . Rosen, An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures, IEEE Trans. Biomed. Eng, vol.37, pp.757-767, 1990.

J. Denoth, E. Stu¨ssistu¨ssi, G. Csucs, and G. Danuser, Single Muscle Fiber Contraction is Dictated by Inter-Sarcomere Dynamics, Journal of Theoretical Biology, vol.216, issue.1, pp.101-122, 2002.
DOI : 10.1006/jtbi.2001.2519

R. Don, A. Ranavolo, A. Cacchio, M. Serrao, F. Costabile et al., Relationship between recovery of calf-muscle biomechanical properties and gait pattern following surgery for achilles tendon rupture, Clinical Biomechanics, vol.22, issue.2, pp.211-220, 2007.
DOI : 10.1016/j.clinbiomech.2006.10.001

C. A. Doorenbosch and J. Harlaar, A clinically applicable EMG???force model to quantify active stabilization of the knee after a lesion of the anterior cruciate ligament, Clinical Biomechanics, vol.18, issue.2, pp.142-149, 2003.
DOI : 10.1016/S0268-0033(02)00183-3

C. A. Doorenbosch and J. Harlaar, Accuracy of a practicable EMG to force model for knee muscles, Neuroscience Letters, vol.368, issue.1, pp.78-81, 2004.
DOI : 10.1016/j.neulet.2004.06.055

T. Finni, P. V. Komi, and J. Lukkariniemi, Achilles tendon loading during walking: application of a novel optic fiber technique, European Journal of Applied Physiology, vol.77, issue.3, pp.289-291, 1998.
DOI : 10.1007/s004210050335

T. Fukunaga, R. R. Roy, F. G. Shellock, J. A. Hodgson, and V. R. Edgerton, Specific tension of human plantar flexors and dorsiflexors, J. Appl. Physiol, vol.80, pp.158-165, 1996.
DOI : 10.1249/00005768-199205001-00337

A. M. Gordon, A. F. Huxley, and F. J. Julian, The variation in isometric tension with sarcomere length in vertebrate muscle fibres, The Journal of Physiology, vol.184, issue.1, pp.170-192, 1966.
DOI : 10.1113/jphysiol.1966.sp007909

K. P. Granata and W. S. Marras, Cost???Benefit of Muscle Cocontraction in Protecting Against Spinal Instability, Spine, vol.25, issue.11, pp.1398-1404, 2000.
DOI : 10.1097/00007632-200006010-00012

H. J. Hermens, B. Freriks, C. Disselhorst-klug, and G. Rau, Development of recommendations for SEMG sensors and sensor placement procedures, Journal of Electromyography and Kinesiology, vol.10, issue.5, pp.361-374, 2000.
DOI : 10.1016/S1050-6411(00)00027-4

A. Hill, The Heat of Shortening and the Dynamic Constants of Muscle, Proceedings of the Royal Society B: Biological Sciences, vol.126, issue.843, p.399, 1938.
DOI : 10.1098/rspb.1938.0050

P. W. Hodges and B. H. Bui, A comparison of computerbased methods for the determination of onset of muscle contraction using electromyography, Electroencephalogr. Clin. Neurophysiol, vol.101, pp.511-519, 1996.

A. L. Hof, In vivo measurement of the series elasticity release curve of human triceps surae muscle, Journal of Biomechanics, vol.31, issue.9, pp.793-800, 1998.
DOI : 10.1016/S0021-9290(98)00062-1

A. L. Hof, J. Van-den, and . Berg, Linearity between the weighted sum of the EMGs of the human triceps surae and the total torque, Journal of Biomechanics, vol.10, issue.9, pp.529-539, 1977.
DOI : 10.1016/0021-9290(77)90033-1

G. Howatson, M. Glaister, J. Brouner, and K. A. Van-someren, The reliability of electromechanical delay and torque during isometric and concentric isokinetic contractions, Journal of Electromyography and Kinesiology, vol.19, issue.5, pp.975-979, 2008.
DOI : 10.1016/j.jelekin.2008.02.002

E. Kellis and A. Katis, Hamstring antagonist moment estimation using clinically applicable models: Muscle dependency and synergy effects, Journal of Electromyography and Kinesiology, vol.18, issue.1, pp.144-153, 2008.
DOI : 10.1016/j.jelekin.2006.09.001

J. L. Krevolin, M. G. Pandy, and J. C. Pearce, Moment arm of the patellar tendon in the human knee, Journal of Biomechanics, vol.37, issue.5, pp.785-788, 2004.
DOI : 10.1016/j.jbiomech.2003.09.010

J. Langenderfer, S. Lascalza, A. Mell, J. E. Carpenter, J. E. Kuhn et al., An EMG-driven model of the upper extremity and estimation of long head biceps force, Computers in Biology and Medicine, vol.35, issue.1, pp.25-39, 2005.
DOI : 10.1016/j.compbiomed.2003.12.002

B. Laursen, B. R. Jensen, G. Ne´methne´meth, and G. Sjøgaard, A model predicting individual shoulder muscle forces based on relationship between electromyographic and 3D external forces in static position, Journal of Biomechanics, vol.31, issue.8, pp.731-739, 1998.
DOI : 10.1016/S0021-9290(98)00091-8

C. W. Linford, J. T. Hopkins, S. S. Schulthies, B. Freland, D. O. Draper et al., Effects of Neuromuscular Training on the Reaction Time and Electromechanical Delay of the Peroneus Longus Muscle, Archives of Physical Medicine and Rehabilitation, vol.87, issue.3, pp.395-401, 2006.
DOI : 10.1016/j.apmr.2005.10.027

K. and T. S. Buchanan, 27 Maganaris, C. N. Force-length characteristics of in vivo human skeletal muscle A one-parameter neural activation to muscle activation model: estimating isometric joint moments from electromyograms, J. Biomech. Acta Physiol. Scand. J. Biomech, vol.36, issue.36, pp.765-776279, 2001.

K. Manal, W. Rose, T. , T. Muramatsu, T. Fukunaga et al., A general solution for the time delay introduced by a low-pass butterworth digital filter: an application to musculoskeletal modeling Influence of tendon slack on electromechanical delay in the human medial gastrocnemius in vivo Lumbarmuscle force estimation using a subject-invariant 5-parameter EMG-based model, J. Biomech. J. Appl. Physiol. J. Biomech, vol.40, issue.31, pp.678-681540, 1998.

G. Rao, D. Amarantini, and E. Berton, Influence of additional load on the moments of the agonist and antagonist muscle groups at the knee joint during closed chain exercise, Journal of Electromyography and Kinesiology, vol.19, issue.3, pp.459-466, 2009.
DOI : 10.1016/j.jelekin.2007.12.001

URL : https://hal.archives-ouvertes.fr/hal-01442067

R. Riener and T. Edrich, Identification of passive elastic joint moments in the lower extremities, Journal of Biomechanics, vol.32, issue.5, pp.539-544, 1999.
DOI : 10.1016/S0021-9290(99)00009-3

L. Schutte, M. Rodgers, F. Zajac, and R. Glaser, Improving the efficacy of electrical stimulation-induced leg cycle ergometry: an analysis based on a dynamic musculoskeletal model, IEEE Transactions on Rehabilitation Engineering, vol.1, issue.2, pp.109-125, 1993.
DOI : 10.1109/86.242425

S. H. Scott and G. E. Loeb, Mechanical properties of aponeurosis and tendon of the cat soleus muscle during whole-muscle isometric contractions, Journal of Morphology, vol.27, issue.1, pp.73-86, 1995.
DOI : 10.1113/jphysiol.1984.sp015077

A. Seth and M. G. Pandy, A neuromusculoskeletal tracking method for estimating individual muscle forces in human movement, Journal of Biomechanics, vol.40, issue.2, pp.356-366, 2007.
DOI : 10.1016/j.jbiomech.2005.12.017

R. Shiavi, C. Frigo, and A. Pedotti, Electromyographic signals during gait: Criteria for envelope filtering and number of strides, Medical & Biological Engineering & Computing, vol.65, issue.2, pp.171-178, 1998.
DOI : 10.1007/BF02510739

M. Solomonow, R. Baratta, B. H. Zhou, H. Shoji, W. Bose et al., The synergistic action of the anterior cruciate ligament and thigh muscles in maintaining joint stability, The American Journal of Sports Medicine, vol.15, issue.3, pp.207-213, 1987.
DOI : 10.1002/ar.1092140216

J. H. Van-diee¨ndiee¨n and B. Visser, Estimating net lumbar sagittal plane moments from EMG data. The validity of calibration procedures, Journal of Electromyography and Kinesiology, vol.9, issue.5, pp.309-315, 1999.
DOI : 10.1016/S1050-6411(99)00004-8

D. A. Winter, Biomechanics and Motor Control of Human Movement, 1990.
DOI : 10.1002/9780470549148

F. Zajac, Muscle and tendon: properties, models, scaling , and application to biomechanics and motor control, Crit. Rev. Biomed. Eng, vol.17, pp.359-411, 1989.