Implicit-Explicit Methods for Time-Dependent Partial Differential Equations, SIAM Journal on Numerical Analysis, vol.32, issue.3, pp.797-823, 1995. ,
DOI : 10.1137/0732037
Air, and Moisture Control in Building Assemblies -Material Properties. In ASHRAE Handbook -Fundamentals, page 1000, p.19, 2013. ,
Simulation program for the calculation of coupled heat, moisture, air, pollutant, and salt transport, 2011. ,
A 2D model for coupled heat, air, and moisture transfer through porous media in contact with air channels, International Journal of Heat and Mass Transfer, vol.95, pp.453-465, 2016. ,
DOI : 10.1016/j.ijheatmasstransfer.2015.12.030
Factors governing the development of moisture disorders for integration into building performance simulation, Journal of Building Engineering, vol.3, pp.1-15 ,
DOI : 10.1016/j.jobe.2015.04.008
An Analysis of Moisture Accumulation in Walls Subjected to Hot and Humid Climates, ASHRAE Transactions, vol.93, issue.16 4, pp.429-439, 1993. ,
Historical Note on the Newton-Raphson Method of Approximation, The American Mathematical Monthly, vol.18, issue.2, pp.29-32, 1911. ,
DOI : 10.2307/2973939
Explicit schemes and numerical simulation using ultrahigh-performance computer systems, Doklady Mathematics, vol.86, issue.2, pp.681-683, 1922. ,
DOI : 10.1134/S1064562412050213
Experimental and numerical analysis of the transient hygrothermal behavior of multilayered hemp concrete wall, Energy and Buildings, vol.112, issue.4, pp.1-11, 2016. ,
DOI : 10.1016/j.enbuild.2015.11.027
A practical method for numerical evaluation of solutions of partial differential equations of the heat-conduction type, Mathematical Proceedings of the Cambridge Philosophical Society, vol.42, issue.01, pp.50-67, 1947. ,
DOI : 10.1098/rsta.1927.0008
Chebfun Guide, p.15 ,
Hygrothermal behaviour of hemp concrete: experimental evidences and modelling, VI International Conference on Computational Methods for Coupled Problems in Science and Engineering, 2015. ,
Computing Qualitatively Correct Approximations of Balance Laws: Exponential- Fit, Well-Balanced and Asymptotic-Preserving, volume 2 of SIMAI Springer Series, p.12, 2013. ,
DOI : 10.1007/978-88-470-2892-0
L-splines and viscosity limits for well-balanced schemes acting on linear parabolic equations, pp.1-21, 2016. ,
Viscous Equations Treated with $$\mathcal{L}$$ -Splines and Steklov-Poincar?? Operator in Two Dimensions, Innovative Algorithms and Analysis, pp.2017-2029 ,
DOI : 10.1063/1.3659943
Solving ordinary differential equations: Nonstiff problems, 2009. ,
DOI : 10.1007/978-3-662-12607-3
Building Pathology: Deterioration, Diagnostics, and Intervention, 2001. ,
Numerical and experimental data set for benchmarking hygroscopic buffering models, International Journal of Heat and Mass Transfer, vol.53, issue.19-20, pp.3638-3654, 2010. ,
DOI : 10.1016/j.ijheatmasstransfer.2010.03.039
Simulation efficiency and accuracy of different moisture transfer potentials, Journal of Building Performance Simulation, vol.9, issue.11, pp.379-389, 2014. ,
DOI : 10.1007/s12273-008-8106-z
Drift-Diffusion Systems: Variational Principles and Fixed Point Maps for Steady State Semiconductor Models, Computational Electronics, pp.15-20, 1991. ,
DOI : 10.1007/978-1-4757-2124-9_2
On a proposed floating-point standard, ACM SIGNUM Newsletter, vol.14, issue.si-2, pp.13-21, 1979. ,
DOI : 10.1145/1057520.1057522
International Energy Agency energy conservation in buildings and community systems programme Heat, air and moisture transfer through new and retrofitted insulated envelope parts: [IEA] (Hamtie); Annex 24 Task 3/Final report: Material properties, Laboratorium Bouwfysica, Dep. Burgerlijke Bouwkunde, K.U.-Leuven, vol.19, issue.5, p.25, 1996. ,
Simultaneous heat and moisture transport in building components: one-and two-dimensional calculation using simple parameters, 1995. ,
Modelling of hysteresis influence on mass transfer in building materials, Building and Environment, vol.44, issue.3, pp.633-642, 2009. ,
DOI : 10.1016/j.buildenv.2008.05.006
Dynamic coupling between vapour and heat transfer in wall assemblies: Analysis of measurements achieved under real climate, Building and Environment, vol.87, pp.129-141, 2005. ,
DOI : 10.1016/j.buildenv.2015.01.022
URL : https://hal.archives-ouvertes.fr/hal-01236296
Hygrothermal behavior of bio-based building materials including hysteresis effects: Experimental and numerical analyses, Energy and Buildings, vol.84, issue.4, pp.617-627, 2014. ,
DOI : 10.1016/j.enbuild.2014.09.013
Development of a Response Factor Approach for Modeling the Energy Effects of Combined Heat and Mass Transfer with Vapor Adsorption in Building Elements, 1994. ,
Study of hygrothermal behaviour of a hemp concrete building envelope under summer conditions in France, Energy and Buildings, vol.77, pp.48-57, 2005. ,
DOI : 10.1016/j.enbuild.2014.03.040
Hygrothermal performance of cross-laminated timber wall assemblies with built-in moisture: field measurements and simulations, Building and Environment, vol.71, pp.95-110, 2004. ,
DOI : 10.1016/j.buildenv.2013.09.008
Models for prediction of heat and moisture transfer through porous building elements, 1997. ,
Numerical methods for diffusion phenomena in building physics, 2016. ,
Umidus: A PC program for the Prediction of Heat and Mass Transfer in Porous Building Elements, IBPSA 99 International Conference on Building Performance Simulation, pp.277-283, 1999. ,
Perturbation Methods, 2000. ,
Non-Fickian moisture diffusion in thermally modified beech wood analyzed by the inverse method, International Journal of Thermal Sciences, vol.109, pp.291-298, 2005. ,
DOI : 10.1016/j.ijthermalsci.2016.06.023
URL : https://hal.archives-ouvertes.fr/hal-01342970
Numerical Heat Transfer and Fluid Flow, United States of America, vol.10, issue.22, pp.12-27, 1980. ,
Stability of the standard Crank-Nicolson-Galerkin Scheme applied to the diffusion-convection equation: Some new insights, Water Resources Research, vol.29, issue.9, pp.3291-3297, 1993. ,
DOI : 10.1002/nme.1620241112
Experimental wooden frame house for the validation of whole building heat and moisture transfer numerical models, Energy and Buildings, vol.43, issue.6, pp.1322-1328, 2005. ,
DOI : 10.1016/j.enbuild.2011.01.008
URL : https://hal.archives-ouvertes.fr/hal-01025211
Dataset for validating 1-D heat and mass transfer models within building walls with hygroscopic materials, Building and Environment, vol.89, pp.356-368, 2015. ,
DOI : 10.1016/j.buildenv.2015.03.008
Analysis aequationum universalis seu adaequationes algebraicas resolvendas methodus generalis, et expedita, ex nova infinitarum serierum doctrina deducta ac demonstrata . Microfilm copy: University Microfilms, pp.1690-1707 ,
Whole Building Hygrothermal Simulation Model, ASHRAE Transactions, vol.109, issue.1 4, pp.572-582, 2003. ,
Physical analysis and hygrothermal caracterisation of construction materials: experimental appraoch and numerical modelling, 2008. ,
Large-signal analysis of a silicon Read diode oscillator, IEEE Transactions on Electron Devices, vol.16, issue.1, pp.64-77, 1969. ,
DOI : 10.1109/T-ED.1969.16566
An experimental data set for benchmarking 1-D, transient heat and moisture transfer models of hygroscopic building materials. Part I: Experimental facility and material property data, International Journal of Heat and Mass Transfer, vol.50, issue.23-24, pp.23-244527, 2007. ,
DOI : 10.1016/j.ijheatmasstransfer.2007.03.026
An experimental data set for benchmarking 1-D, transient heat and moisture transfer models of hygroscopic building materials. Part II: Experimental, numerical and analytical data, International Journal of Heat and Mass Transfer, vol.50, issue.25-26, pp.25-264915, 2007. ,
DOI : 10.1016/j.ijheatmasstransfer.2007.03.025
Transient model for coupled heat, air and moisture transfer through multilayered porous media, International Journal of Heat and Mass Transfer, vol.53, issue.15-16, pp.15-163035, 2010. ,
DOI : 10.1016/j.ijheatmasstransfer.2010.03.024
Benchmark experiments for moisture transfer modelling in air and porous materials, Building and Environment, vol.46, issue.4, pp.884-898, 2005. ,
DOI : 10.1016/j.buildenv.2010.10.018
Tools for performance simulation of heat, air and moisture conditions of whole buildings, Building Simulation, vol.2, issue.112, pp.5-24, 2008. ,
DOI : 10.1007/s12273-008-8106-z
URL : https://hal.archives-ouvertes.fr/hal-00353433
Brazil E-mail address: Julien.Berger@pucpr.edu.br URL: https://www.researchgate.net/profile/Julien_Berger3/ S. Gasparin: Thermal Systems Laboratory, Mechanical Engineering Graduate Program , Pontifical Catholic University of Paraná, Rua Imaculada Conceição Brazil E-mail address: suelengasparin@hotmail.com URL: https://www.researchgate.net/profile Campus Scientifique , F-73376 Le Bourget-du-Lac Cedex, France E-mail address: Denys.Dutykh@univ-savoie.fr URL: http://www.denys-dutykh, pp.80215-901, 1155. ,