M. Kamionka, P. Breuil, and C. Pijolat, Calibration of a multivariate gas sensing device for atmospheric pollution measurement, Sensors and Actuators B: Chemical, vol.118, issue.1-2, pp.323-327, 2006.
DOI : 10.1016/j.snb.2006.04.058

URL : https://hal.archives-ouvertes.fr/emse-00430755

N. Yamazoe and K. Shimanoe, New perspectives of gas sensor technology, Sensors and Actuators B: Chemical, vol.138, issue.1, pp.100-107, 2009.
DOI : 10.1016/j.snb.2009.01.023

Y. Ma, M. Richards, M. Ghanem, Y. Guo, and J. Hassard, Air Pollution Monitoring and Mining Based on Sensor Grid in London, Sensors, pp.3601-3623, 2008.

P. Ködderitzsch, R. Bischofa, P. Veitenhansl, W. Lorenz, and G. Bischoff, Sensor array based measurement technique for fast-responding cigarette smoke analysis, Sensors and Actuators B: Chemical, vol.107, issue.1, pp.479-489, 2005.
DOI : 10.1016/j.snb.2004.11.007

C. Pijolat, C. Pupier, M. Sauvan, G. Tournier, and R. Laulauze, Gas detection for automotive pollution control, Sensors and Actuators B: Chemical, vol.59, issue.2-3, pp.195-202, 1999.
DOI : 10.1016/S0925-4005(99)00220-8

J. B. Rivière, C. Viricelle, and . Pijolat, Development of tin oxide material by screenprinting technology for micro-machined gas sensorsSensors and Actuators B, pp.531-537, 2003.

M. Kamionka, P. Breuil, and C. Pijolat, Atmospheric pollution measurement with a multi-materials sensing device, Materials Science and Engineering: C, vol.26, issue.2-3, pp.290-296, 2006.
DOI : 10.1016/j.msec.2005.10.047

URL : https://hal.archives-ouvertes.fr/emse-00430728

J. Watson, The tin oxide gas sensor and its applications, Sensors and Actuators, vol.5, issue.1, pp.250-687487004, 1984.
DOI : 10.1016/0250-6874(84)87004-3

S. Zampolli, I. Elmi, F. Ahmed, M. Passini, G. Cardinali et al., An electronic nose based on solid state sensor arrays for low-cost indoor air quality monitoring applications, Sensors and Actuators B: Chemical, vol.101, issue.1-2, pp.39-46, 2004.
DOI : 10.1016/j.snb.2004.02.024

M. Padilla, A. Perera, I. Montoliu, A. Chaudry, K. Persaud et al., Drift compensation of gas sensor array data by Orthogonal Signal Correction, Chemometrics and Intelligent Laboratory Systems, vol.100, issue.1, pp.28-35, 2010.
DOI : 10.1016/j.chemolab.2009.10.002

O. Tomic, H. Ulmer, and J. E. Haugen, Standardization methods for handling instrument related signal shift in gas-sensor array measurement data, Analytica Chimica Acta, vol.472, issue.1-2, pp.99-111, 2002.
DOI : 10.1016/S0003-2670(02)00936-4

G. Korotcenkov and B. Cho, Instability of metal oxide-based conductometric gas sensors and approaches to stability improvement (short survey), Sensors and Actuators B: Chemical, vol.156, issue.2, pp.527-538, 2011.
DOI : 10.1016/j.snb.2011.02.024

A. C. Romain and J. Nicolas, Long term stability of metal oxide-based gas sensors for e-nose environmental applications: An overview, Sensors and Actuators B: Chemical, vol.146, issue.2, pp.502-506, 2010.
DOI : 10.1016/j.snb.2009.12.027

D. Vito, M. Piga, L. Martinotto, G. D. Francia, and . Co, CO, NO2 and NOx urban pollution monitoring with on-field calibrated electronic nose by automatic bayesian regularization, Sensors and Actuators B: Chemical, vol.143, issue.1, pp.182-191, 2009.
DOI : 10.1016/j.snb.2009.08.041

O. Tomic, T. Eklöv, K. Kvaal, and J. Haugen, Recalibration of a gas-sensor array system related to sensor replacement, Analytica Chimica Acta, vol.512, issue.2, pp.199-206, 2004.
DOI : 10.1016/j.aca.2004.03.001

R. Shaffer, S. Rose-pehrsson, and R. Mcgill, A comparison study of chemical sensor array pattern recognition algorithms, Analytica Chimica Acta, vol.384, issue.3, pp.305-317, 1999.
DOI : 10.1016/S0003-2670(98)00780-6

V. Sommer, P. Tobias, D. Kohl, H. Sundgren, and I. Lundstriim, Neural networks and abductive networks for chemical sensor signals: a case comparison, Sensors and Actuators B: Chemical, vol.28, issue.3, pp.217-2220925, 1995.
DOI : 10.1016/0925-4005(95)01721-6

C. D. Natale, F. Davide, and A. , Pattern recognition in gas sensing: well-stated techniques and advances, Sensors and Actuators B: Chemical, vol.23, issue.2-3, pp.111-1180925, 1995.
DOI : 10.1016/0925-4005(94)01279-2

E. Hines, E. Llobet, and J. Gardner, Electronic noses: a review of signal processing techniques IEEE Proceedings ? Circuits Devices and Systemes 146, pp.297-310, 1999.

P. Szecowka, A. Szuczurek, and B. Licznerski, On reliability of neural network sensitivity analysis applied for sensor array optimization, Sensors and Actuators B: Chemical, vol.157, issue.1, pp.298-303, 2011.
DOI : 10.1016/j.snb.2011.03.066

R. M. Negri, S. Reich, and S. , Identification of pollutant gases and its concentrations with a multisensor array, Sensors and Actuators B: Chemical, vol.75, issue.3, pp.172-178, 2001.
DOI : 10.1016/S0925-4005(01)00543-3

W. Bourgeois, The use of sensor arrays for environmental monitoring: interests and limitations, Journal of Environmental Monitoring, vol.5, issue.6, pp.852-860, 2003.
DOI : 10.1039/b307905h

W. Tsujita, A. Yoshino, H. Ishida, and T. Moriizumi, Gas sensor network for air-pollution monitoring, Sensors and Actuators B: Chemical, vol.110, issue.2, pp.304-311, 2005.
DOI : 10.1016/j.snb.2005.02.008

H. Shurmer, P. Corcoran, and M. James, Sensitivity enhancement for gas sensing and electronic nose applications, Sensors and Actuators B: Chemical, vol.16, issue.1-3, pp.256-2590925, 1993.
DOI : 10.1016/0925-4005(93)85191-C

L. A. Zadeh, Fuzzy sets, Information and Control, vol.8, issue.3, pp.338-353, 1965.
DOI : 10.1016/S0019-9958(65)90241-X