Error compensation in machine tools ??? a review, International Journal of Machine Tools and Manufacture, vol.40, issue.9, pp.1235-1256, 2000. ,
DOI : 10.1016/S0890-6955(00)00009-2
CMM verification: a survey, Measurement, vol.17, issue.1, pp.1-16, 1996. ,
DOI : 10.1016/0263-2241(96)00001-2
Comparison of different artefacts for interim coordinate-measuring machine checking: a report from the Swiss Standards Committee, Precision Engineering, vol.13, issue.4, pp.277-2910141, 1991. ,
DOI : 10.1016/0141-6359(91)90006-5
Multiple orientation technique for the calibration of cylindrical workpieces on CMMs, Precision Engineering, vol.29, issue.1, pp.56-64, 2005. ,
DOI : 10.1016/j.precisioneng.2004.04.006
Calibration of coordinate measuring machines, Precision Engineering, vol.7, issue.3, pp.139-1440141, 1985. ,
DOI : 10.1016/0141-6359(85)90036-4
Development of computer integrated system for error diagnosis of a CMM using calibrated mechanical artefacts, International Journal of Machine Tools and Manufacture, vol.33, issue.6, pp.773-7900890, 1993. ,
DOI : 10.1016/0890-6955(93)90037-U
A simple method for testing measuring machines and machine tools Part 1: Principles and applications, Precision Engineering, vol.4, issue.2, pp.61-690141, 1982. ,
DOI : 10.1016/0141-6359(82)90018-6
Theory and simulation for the identification of the link geometric errors for a five-axis machine tool using a telescoping magnetic ball-bar, International Journal of Production Research, vol.32, issue.18, pp.4781-4797, 2002. ,
DOI : 10.1016/0278-6125(91)90058-A
Theoretical Modelisation and Experimental Identification of the Geometrical Parameters of Coordinate-Machines by Measuring a Multi-Directed Bar, CIRP Annals - Manufacturing Technology, vol.35, issue.1, pp.393-396, 1986. ,
DOI : 10.1016/S0007-8506(07)61913-1
A Method for Machine Geometry Calibration Using 1-D Ball Array, CIRP Annals - Manufacturing Technology, vol.40, issue.1, pp.519-522, 1991. ,
DOI : 10.1016/S0007-8506(07)62044-7
Ball array calibration on a coordinate measuring machine using a gage block, Measurement, vol.16, issue.4, pp.219-2290263, 1995. ,
DOI : 10.1016/0263-2241(95)00035-6
Rapid volumetric calibration of coordinate measuring machines using a hole bar artefact, Proceedings of the Institution of Mechanical Engineers, pp.1083-1093, 2002. ,
DOI : 10.1243/095440502760272368
Creating a Standards Infrastructure for Co-Ordinate Measurement Technology in the UK, CIRP Annals - Manufacturing Technology, vol.38, issue.1, pp.521-523, 1989. ,
DOI : 10.1016/S0007-8506(07)62759-0
A Uniform Concept for Calibration, Acceptance Test, and Periodic Inspection of Coordinate Measuring Machines Using Reference Objects, CIRP Annals - Manufacturing Technology, vol.39, issue.1, pp.561-564, 1990. ,
DOI : 10.1016/S0007-8506(07)61119-6
A reference object based method to determine the parametric error components of coordinate measuring machines and machine tools, Measurement, vol.9, issue.1, pp.17-220263, 1991. ,
DOI : 10.1016/0263-2241(91)90022-I
Calibration of a 3D-ball plate, Precision Engineering, vol.33, issue.1, pp.1-6, 2009. ,
DOI : 10.1016/j.precisioneng.2008.02.003
Machine tool calibration: Geometric test uncertainty depends on machine tool performance, Precision Engineering, vol.33, issue.4, pp.0141635908000342-524, 2009. ,
DOI : 10.1016/j.precisioneng.2009.02.002
Standards for testing freeform measurement capability of optical and tactile coordinate measuring machines, 2012) 094013. URL http://stacks.iop.org, pp.957-0233 ,
DOI : 10.1088/0957-0233/23/9/094013
A modular space frame for assessing the performance of co-ordinate measuring machines (CMMs), Precision Engineering, vol.26, issue.1, pp.37-48, 2002. ,
DOI : 10.1016/S0141-6359(01)00096-4
Reduction of machining errors of a three-axis machine tool by on-machine measurement and error compensation system, Journal of Materials Processing Technology, vol.155, issue.156, pp.2056-2064, 2004. ,
DOI : 10.1016/j.jmatprotec.2004.04.402
Five-axis machine tool calibration by probing a scale enriched reconfigurable uncalibrated master balls artefact, {CIRP} Annals -Manufacturing Technology, pp.515-518, 2012. ,
A machining test to calibrate rotary axis error motions of five-axis machine tools and its application to thermal deformation test, International Journal of Machine Tools and Manufacture, vol.86, issue.0, pp.81-88, 2014. ,
DOI : 10.1016/j.ijmachtools.2014.07.005
Kinematic errors identification of three-axis machine tools based on machined work pieces, Precision Engineering, vol.43, 2015. ,
DOI : 10.1016/j.precisioneng.2015.09.018
Dynamic calibration of the positioning accuracy of machine tools and coordinate measuring machines using a laser interferometer, International Journal of Machine Tools and Manufacture, vol.43, issue.9, pp.947-954, 2003. ,
DOI : 10.1016/S0890-6955(03)00083-X
Error mapping of CMMs and machine tools by a single tracking interferometer, CIRP Annals - Manufacturing Technology, vol.54, issue.1, pp.475-478, 2005. ,
DOI : 10.1016/S0007-8506(07)60148-6
Influence of measurement noise and laser arrangement on measurement uncertainty of laser tracker multilateration in machine tool volumetric verification, Geometrical product specifications (GPS) ? geometrical tolerancing ? datums and datum systems, pp.929-943, 1993. ,
DOI : 10.1016/j.precisioneng.2013.03.006
Evaluation of roundness error using a new method based on a small displacement screw, 2014) 044012. URL http://stacks.iop.org, pp.957-0233 ,
DOI : 10.1088/0957-0233/25/4/044012
URL : https://hal.archives-ouvertes.fr/hal-01140113
Self-Calibration: Reversal, Redundancy, Error Separation, and ???Absolute Testing???, CIRP Annals - Manufacturing Technology, vol.45, issue.2, pp.617-634, 1996. ,
DOI : 10.1016/S0007-8506(07)60515-0
Industrial automation systems and integration ? numerical control of machines ? coordinate system and motion nomenclature, 2004. ,
Modèle d'identification geométrique des surfaces, Métrologie fonctionnelle des pì eces mécaniques, Correction géométrique des machinesàmachines`machinesà mesurer tridimensionnelles , Doctorat d'´ etat Es-Sciences Physiques, 1987. ,