Stimulus artifact removal in EMG from muscles adjacent to stimulated muscles, Journal of Neuroscience Methods, vol.64, issue.1, pp.55-62, 1996. ,
DOI : 10.1016/0165-0270(95)00099-2
The abc of emg, A practical introduction to kinesiological electromyography 1, 2005. ,
Recent progress in the diagnostic use of surface EMG for neurological diseases, Journal of Electromyography and Kinesiology, vol.10, issue.5, pp.287-291, 2000. ,
DOI : 10.1016/S1050-6411(00)00020-1
Stimulation artifact in surface emg signal: effect of the stimulation waveform, detection system, and current amplitude using hybrid stimulation technique, Neural Systems and Rehabilitation Engineering, IEEE Transactions on, vol.11, issue.4, pp.407-415, 2003. ,
Suppression of stimulation artifacts from myoelectric-evoked potential recordings, IEEE Transactions on Biomedical Engineering, vol.35, issue.9, pp.758-763, 1988. ,
DOI : 10.1109/10.7278
Techniques of EMG signal analysis: detection, processing, classification and applications, Biological Procedures Online, vol.13, issue.2, pp.11-35, 2006. ,
DOI : 10.1251/bpo115
A technique for recording the emg of electrically stimulated skeletal muscle, Orthopedics, vol.8, issue.4, p.492, 1985. ,
A digital averaging method for removal of stimulus artifacts in neurophysiologic experiments, Journal of Neuroscience Methods, vol.98, issue.1, pp.57-62, 2000. ,
DOI : 10.1016/S0165-0270(00)00190-4
Microcomputer based electromyographic recording system with stimulus artifact suppression, Third Medical Conference on Biomedical Engineering, Portoroz Yugoslavia, 1983. ,
A simplified circuit for stimulus artifact suppression, Electroencephalography and Clinical Neurophysiology, vol.39, issue.1, pp.85-87, 1975. ,
DOI : 10.1016/0013-4694(75)90130-3
An electronic stimulus artifact suppressor, Electroencephalography and Clinical Neurophysiology, vol.31, issue.2, pp.170-172, 1971. ,
DOI : 10.1016/0013-4694(71)90188-X
A sample and hold amplifier system for stimulus artifact suppression, Electroencephalography and Clinical Neurophysiology, vol.44, issue.4, pp.528-531, 1978. ,
DOI : 10.1016/0013-4694(78)90038-X
Instrumentation for ENG and EMG recordings in FES systems, IEEE Transactions on Biomedical Engineering, vol.41, issue.7, pp.703-706, 1994. ,
DOI : 10.1109/10.301739
On the Nature and Elimination of Stimulus Artifact in Nerve Signals Evoked and Recorded Using Surface Electrodes, IEEE Transactions on Biomedical Engineering, vol.29, issue.2, pp.129-137, 1982. ,
DOI : 10.1109/TBME.1982.325019
Adaptive stimulus artifact cancellation in gastric myoelectrical signals, Proceedings of the 20th Annual International Conference of the IEEE, pp.1636-1639, 1998. ,
Stimulus artifact removal using a software-based two-stage peak detection algorithm, Journal of Neuroscience Methods, vol.109, issue.2, pp.137-145, 2001. ,
DOI : 10.1016/S0165-0270(01)00407-1
A method for eliminating the stimulus artifact from digital recordings of the direct cortical response, Computers and Biomedical Research, vol.24, issue.2, pp.183-195, 1991. ,
DOI : 10.1016/0010-4809(91)90029-V
Real-time multi-channel stimulus artifact suppression by local curve fitting, Journal of Neuroscience Methods, vol.120, issue.2, pp.113-120, 2002. ,
DOI : 10.1016/S0165-0270(02)00149-8
Comparison of adaptive systems for suppression of stimulation artifacts in EMG signals, Proceedings of First International Caracas Conference on Devices, Circuits and Systems, pp.144-148, 1995. ,
DOI : 10.1109/ICCDCS.1995.499133
Electromyography: Some Methodological Problems and Issues, Physical Therapy, vol.73, issue.10, pp.698-710, 1993. ,
DOI : 10.1093/ptj/73.10.698
Wavelet basis functions in biomedical signal processing, Expert Systems with Applications, vol.38, issue.5, pp.6190-6201, 2011. ,
DOI : 10.1016/j.eswa.2010.11.050
M-wave properties during progressive motor unit activation by transcutaneous stimulation, Journal of Applied Physiology, vol.97, issue.2, pp.545-555, 2004. ,
DOI : 10.1152/japplphysiol.00064.2004
A real time electromyostimulator linked with EMG analysis device, IRBM, vol.34, issue.1, pp.43-47, 2013. ,
DOI : 10.1016/j.irbm.2012.12.003
URL : https://hal.archives-ouvertes.fr/hal-00826684
Estimation of Muscular Fatigue Under Electromyostimulation Using CWT, IEEE Transactions on Biomedical Engineering, vol.59, issue.12, 2012. ,
DOI : 10.1109/TBME.2012.2215031
URL : https://hal.archives-ouvertes.fr/hal-00785291
Surface EMG processing: Introduction to the special issue, Biomedical Signal Processing and Control, vol.3, issue.2, pp.115-117, 2008. ,
DOI : 10.1016/j.bspc.2008.01.001
Image analysis and mathematical morphology, 1982. ,
Electrically evoked myoelectric signals, Crit Rev Biomed Eng, vol.19, issue.4, pp.293-340, 1992. ,