L. Blunt, P. Bills, X. Jiang, C. Hardaker, and G. Chakrabarty, The role of tribology and metrology in the latest development of bio-materials, Wear, vol.266, issue.3-4, pp.424-431, 2009.
DOI : 10.1016/j.wear.2008.04.015

S. L. Bevill, G. R. Bevill, J. R. Penmetsa, A. J. Petrella, and P. J. Rullkoetter, Finite element simulation of early creep and wear in total hip arthroplasty, Journal of Biomechanics, vol.38, issue.12, pp.38-2365, 2005.
DOI : 10.1016/j.jbiomech.2004.10.022

S. H. Teoh, W. H. Chan, and R. Thampuran, An elasto-plastic finite element model for polyethylene wear in total hip arthroplasty, Journal of Biomechanics, vol.35, issue.3, pp.323-330, 2002.
DOI : 10.1016/S0021-9290(01)00215-9

J. S. Wu, J. P. Hung, C. S. Shu, and J. H. Chen, The computer simulation of wear behavior appearing in total hip prosthesis, Computer Methods and Programs in Biomedicine, vol.70, issue.1, pp.70-81, 2003.
DOI : 10.1016/S0169-2607(01)00199-7

T. A. Maxian, T. D. Brown, D. R. Pedersen, and J. J. Callaghan, A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty, Journal of Biomechanics, vol.29, issue.5, pp.687-692, 1996.
DOI : 10.1016/0021-9290(95)00125-5

J. G. Bowsher and J. C. Shelton, A hip simulator study of the influence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions, Wear, vol.250, issue.1-12, pp.167-179, 2001.
DOI : 10.1016/S0043-1648(01)00619-6

V. A. González-mora, M. Hoffmann, R. Stroosnijder, and F. J. Gil, Wear tests in a hip joint simulator of different CoCrMo counterfaces on UHMWPE, Materials Science and Engineering: C, vol.29, issue.1, pp.153-158, 2009.
DOI : 10.1016/j.msec.2008.06.006

S. Affatato, M. Spinelli, M. Zavalloni, C. Mazzega-fabbro, and M. Viceconti, Tribology and total hip joint replacement: Current concepts in mechanical simulation, Medical Engineering & Physics, vol.30, issue.10, pp.30-1305, 2008.
DOI : 10.1016/j.medengphy.2008.07.006

J. Geringer, B. Boyer, and F. Farizon, Understanding the dual mobility concept for total hip arthroplasty. Investigations on a multiscale analysis-highlighting the role of arthrofibrosis, Wear, vol.271, issue.9-10, pp.2379-2385, 2011.
DOI : 10.1016/j.wear.2011.02.027

URL : https://hal.archives-ouvertes.fr/hal-00620858

R. M. Hall, A. Unsworth, P. Siney, and B. M. Wroblewski, Wear in retrieved Charnley acetabular sockets, ARCHIVE: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 1989-1996 (vols 203-210), vol.210, issue.38, pp.197-207, 1996.
DOI : 10.1243/PIME_PROC_1996_210_413_02

M. Jasty, D. D. Goetz, C. R. Bradgon, K. R. Lee, A. E. Hanson et al., Wear of polyethylene acetabular components in total hip arthroplasty, The Journal of Bone and Joint Surgery, pp.79-349, 1997.

B. Morris, L. Zou, M. Royle, D. Simpson, and J. C. Shelton, Quantifying the wear of acetabular cups using coordinate metrology, Wear, vol.271, issue.7-8, pp.1086-1092, 2011.
DOI : 10.1016/j.wear.2011.05.014

M. Tuke, A. Taylor, A. Roques, and C. , 3D linear and volumetric wear measurement on artificial hip joints???Validation of a new methodology, Precision Engineering, vol.34, issue.4, pp.777-783, 2010.
DOI : 10.1016/j.precisioneng.2010.06.001

H. C. Kandpal, D. S. Mehta, and J. S. Vaishya, Simple method for measurement of surface roughness using spectral interferometry, Optics and Lasers in Engineering, vol.34, issue.3, pp.139-148, 2000.
DOI : 10.1016/S0143-8166(00)00098-1

B. Dhanasekar and B. Ramamoorthy, Digital speckle interferometry for assessment of surface roughness, Optics and Lasers in Engineering, vol.46, issue.3, pp.272-280, 2008.
DOI : 10.1016/j.optlaseng.2007.09.003

U. P. Kumar, B. Bhaduri, M. P. Kothiyal, and N. K. Mohan, Two-wavelength micro-interferometry for 3-D surface profiling, Optics and Lasers in Engineering, vol.47, issue.2, pp.47-223, 2009.
DOI : 10.1016/j.optlaseng.2008.04.005

K. J. Stout and L. Blunt, Nanometers to micrometers: three-dimensional surface measurement in bio-engineering, Surf. Coat. Tech, pp.71-69, 1995.

C. Y. Poon and B. Bhushan, Comparison of surface roughness measurements by stylus profiler, AFM and non-contact optical profiler, Wear, vol.190, issue.1, pp.76-88, 1995.
DOI : 10.1016/0043-1648(95)06697-7

J. Yun, S. Chang, T. Xie, L. Zhang, and G. Hu, A novel contact and non-contact hybrid profilometer, Precision Engineering, vol.33, issue.2
DOI : 10.1016/j.precisioneng.2008.06.002

A. Taguchi, T. Miyoshi, Y. Takaya, and S. Takahashi, Optical 3D profilometer for in-process measurement of microsurface based on phase retrieval technique, Precision Engineering, vol.28, issue.2, pp.152-163, 2004.
DOI : 10.1016/j.precisioneng.2003.07.002

V. G. Badami, S. T. Smith, R. J. Raja, and . Hocken, A portable three-dimensional stylus profile measuring instrument, Precision Engineering, vol.18, issue.2-3, pp.147-156, 1996.
DOI : 10.1016/0141-6359(95)00071-2

D. Najjar, M. Bigerelle, H. Migaud, and A. Iost, About the relevance of roughness parameters used for characterizing worn femoral heads, Tribology International, vol.39, issue.12, pp.1527-1537, 2006.
DOI : 10.1016/j.triboint.2006.01.018

A. M. Brown, A new software for carrying out one-way ANOVA post hoc tests, Computer Methods and Programs in Biomedicine, vol.79, issue.1, pp.89-95, 2005.
DOI : 10.1016/j.cmpb.2005.02.007

F. Curtin and P. Schulz, Multiple correlations and bonferroni???s correction, Biological Psychiatry, vol.44, issue.8, pp.775-777, 1998.
DOI : 10.1016/S0006-3223(98)00043-2

V. Saikko and M. Shen, Wear comparison between a dual mobility total hip prosthesis and a typical modular design using a hip joint simulator, Wear, vol.268, issue.3-4, pp.617-621, 2010.
DOI : 10.1016/j.wear.2009.10.011

S. Affatato, G. Bersaglia, M. Rocchi, P. Taddei, C. Fagnano et al., Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions, Biomaterials, vol.26, issue.16, pp.3259-3267, 2005.
DOI : 10.1016/j.biomaterials.2004.07.070

Y. Wu, S. Liu, and G. Zhang, Improvement of coordinate measuring machine probing accessibility, Precision Engineering, vol.28, issue.1, pp.89-94, 2004.
DOI : 10.1016/S0141-6359(03)00080-1

M. P. Sutcliffe, Surface asperity deformation in metal forming processes, International Journal of Mechanical Sciences, vol.30, issue.11, pp.847-868, 1988.
DOI : 10.1016/0020-7403(88)90010-0

C. Units, . Equations, and . Notation, C1. Check your use of units and convert to SI where necessary