High-accuracy x-ray line standards in the 3-keV region - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Physical Review A : Atomic, molecular, and optical physics [1990-2015] Année : 2013

High-accuracy x-ray line standards in the 3-keV region

S. Schlesser
  • Fonction : Auteur
S. Boucard
  • Fonction : Auteur
D. S. Covita
  • Fonction : Auteur
J. M. F. Dos Santos
  • Fonction : Auteur
H. Fuhrmann
  • Fonction : Auteur
D. Gotta
  • Fonction : Auteur
A. Gruber
  • Fonction : Auteur
M. Hennebach
  • Fonction : Auteur
A. Hirtl
  • Fonction : Auteur
P. Indelicato
E. -O. Le Bigot
  • Fonction : Auteur
L. M. Simons
  • Fonction : Auteur
L. Stingelin
  • Fonction : Auteur
J. F. C. A. Veloso
  • Fonction : Auteur
A. Wasser
  • Fonction : Auteur
J. Zmeskal
  • Fonction : Auteur

Résumé

A set of 14 high-accuracy x-ray transition energies in the 2.4-3.1 keV range is presented, which can be used as x-ray standards. They were measured in two-to four-electron sulfur, chlorine, and argon ions produced in an electron-cyclotron resonance ion source, using a single spherically bent crystal spectrometer. The results include the first measurement of six transitions and improve the accuracy of six other experimental values. These measurements considerably extend the set of high-accuracy x-ray energies reported for highly charged ions. Their relative uncertainties range from 1 to 10 ppm. Theory only reaches such a precision in one-and two-electron ions. Our results thus have two distinct applications. On the one hand, they test predictions in two-electron ions [Artemyev, Shabaev, Yerokhin, Plunien, and Soff, Phys. Rev. A 71, 062104 (2005)], at the precision level of some two-photon QED contributions. We observe an agreement with theory for most of the transitions. On the other hand, the three-and four-electron ion transitions provide new benchmark energies for the calculation of missing theoretical contributions, such as Auger shifts or electronic correlations. Spectra were analyzed with an x-ray tracing simulation that contains all the relevant physics of the spectrometer.

Dates et versions

hal-01245591 , version 1 (17-12-2015)

Identifiants

Citer

S. Schlesser, S. Boucard, D. S. Covita, J. M. F. Dos Santos, H. Fuhrmann, et al.. High-accuracy x-ray line standards in the 3-keV region. Physical Review A : Atomic, molecular, and optical physics [1990-2015], 2013, 88 (2), pp.022503. ⟨10.1103/PhysRevA.88.022503⟩. ⟨hal-01245591⟩
50 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More