POD study of aerated cavitation in a venturi nozzle
Résumé
The fact of injecting bubbles into a cavitating flow influences typical cavitating
behavior. Cavitation and aerated cavitation experiments has been carried out on a symmetrical
venturi nozzle with convergent/divergent angles of 18 ◦ and 8 ◦ , respectively. A snapshot Proper
Orthogonal Decomposition (POD) technique is used to identify different modes in terms of
discharge flow velocity, pressure and injected quantity of air. The energy spectrum per given
mode is also presented. The first four modes are outlined in the present paper for an aerated
and non-aerated cavitating flows.