M. Salathe, Regulation of Mammalian Ciliary Beating, Annual Review of Physiology, vol.69, issue.1, pp.401-422, 2007.
DOI : 10.1146/annurev.physiol.69.040705.141253

M. Garcia, Hypothalamic ependymal-glial cells express the glucose transporter GLUT2, a protein involved in glucose sensing, Journal of Neurochemistry, vol.44, issue.3, pp.709-724, 2003.
DOI : 10.1016/0026-0495(95)90074-8

W. Kim, T. Han, H. Kim, M. Park, K. Kim et al., An Automated Measurement of Ciliary Beating Frequency using a Combined Optical Flow and Peak Detection, Healthcare Informatics Research, vol.17, issue.2, pp.111-120, 2011.
DOI : 10.4258/hir.2011.17.2.111

W. Yi, K. Park, C. Lee, C. Rhee, and S. Nam, Directional disorder of ciliary metachronal waves using two-dimensional correlation map, IEEE Trans Biomed Eng, vol.49, issue.3, pp.269-73, 2002.

W. Yi, K. Park, C. Lee, and C. Rhee, Correlation between ciliary beat frequency and metachronal wave disorder using image analysis method, Medical & Biological Engineering & Computing, vol.49, issue.4, pp.481-486, 2003.
DOI : 10.1164/ajrccm/151.3_Pt_1.800

O. Callaghan and C. , Analysis of ependymal ciliary beat pattern and beat frequency using high speed imaging: comparison with the photomultiplier and photodiode methods, Cilia, vol.1, issue.1, p.8, 2012.
DOI : 10.1002/cm.970050402

S. Dimova, F. Maes, M. Brewster, M. Jorissen, M. Noppe et al., High-speed digital imaging method for ciliary beat frequency measurement, Journal of Pharmacy and Pharmacology, vol.211, issue.4, pp.521-526, 2005.
DOI : 10.1046/j.1365-2818.2003.01209.x

O. Meste, F. Brau, and A. Guyon,

W. Yi, K. Park, Y. Min, and M. Sung, Distribution mapping of ciliary beat frequencies of respiratory epithelium cells using image processing, Medical & Biological Engineering & Computing, vol.73, issue.6, pp.595-604, 1997.
DOI : 10.1007/BF02510966

M. Olm, J. Kogler, M. Macchione, A. Shoemark, P. Saldiva et al., Primary ciliary dyskinesia: evaluation using cilia beat frequency assessment via spectral analysis of digital microscopy images, Journal of Applied Physiology, vol.67, issue.1, pp.295-302, 2011.
DOI : 10.1164/rccm.200903-0459OC

A. Oldenburg, R. Chhetri, D. Hill, and B. Button, Monitoring airway mucus flow and ciliary activity with optical coherence tomography, Biomedical Optics Express, vol.3, issue.9, pp.1978-92, 2012.
DOI : 10.1364/BOE.3.001978.m007

G. Conductier, F. Brau, A. Viola, F. Langlet, N. Ramkumar et al., Melanin-concentrating hormone regulates beat frequency of ependymal cilia and ventricular volume, Nature Neuroscience, vol.107, issue.7, 2013.
DOI : 10.1007/s10519-006-9077-4

URL : https://hal.archives-ouvertes.fr/hal-00827897

R. Doyle, T. Moninger, N. Debavalya, and W. Hsu, Use of confocal linescan to document ciliary beat frequency, Journal of Microscopy, vol.546, issue.2, pp.159-64, 2006.
DOI : 10.1016/S0378-1135(99)00176-5

K. Lechtrek, M. Sanderson, and G. Witman, High-Speed Digital Imaging of Ependymal Cilia in the Murine Brain, Methods in Cell Biol, issue.91, pp.255-264, 2009.
DOI : 10.1016/S0091-679X(08)91013-X

K. Lechtrek, P. Delmotte, M. Robinson, M. Sanderson, and G. Witman, impair ciliary motility in mice, The Journal of Cell Biology, vol.138, issue.3, pp.633-676, 2008.
DOI : 10.1002/cm.20189

M. Schoberl, S. Fossel, and A. Kaup, Fixed pattern noise column drift compensation (CDC) for digital moving picture cameras, 2010 IEEE International Conference on Image Processing, pp.573-576, 2010.
DOI : 10.1109/ICIP.2010.5652732

B. Zitova and J. Flusser, Image registration methods: a survey, Image and Vision Computing, vol.21, issue.11, pp.977-1000, 2003.
DOI : 10.1016/S0262-8856(03)00137-9

M. Chilvers, O. Callaghan, and C. , Analysis of ciliary beat pattern and beat frequency using digital high speed imaging: comparison with the photomultiplier and photodiode methods, Thorax, vol.55, issue.4, pp.314-317, 2000.
DOI : 10.1136/thorax.55.4.314

URL : http://thorax.bmj.com/content/thoraxjnl/55/4/314.full.pdf

S. Kay, Fundamentals of Statistical Signal Processing, 1993.

C. Smith, J. Djakow, R. Free, P. Djakow, R. Lonnen et al., ciliaFA: a research tool for automated, high-throughput measurement of ciliary beat frequency using freely available software, Cilia, vol.1, issue.1
DOI : 10.1016/0167-4781(89)90131-0

URL : https://doi.org/10.1186/2046-2530-1-14

D. Bigio and M. , Ependymal cells: biology and pathology, Acta Neuropathologica, vol.27, issue.Suppl 5, pp.55-73, 2010.
DOI : 10.1002/j.1550-8528.1995.tb00496.x

A. Psarra, Immunocytochemical localization of glycogen phosphorylase kinase in rat brain sections and in glial and neuronal primary cultures, Journal of Neurocytology, vol.27, issue.11, pp.779-790, 1998.
DOI : 10.1023/A:1006970429961

Z. Teff, Z. Priel, and L. Gheber, The Forces Applied by Cilia Depend Linearly on Their Frequency Due to Constant Geometry of the Effective Stroke, Biophysical Journal, vol.94, issue.1, pp.298-305, 2008.
DOI : 10.1529/biophysj.107.111724

L. Liu, Method for Quantitative Study of Airway Functional Microanatomy Using Micro-Optical Coherence Tomography, PLoS ONE, vol.138, issue.1, 2013.
DOI : 10.1371/journal.pone.0054473.s005

URL : https://doi.org/10.1371/journal.pone.0054473