Performance tests of prototype high-field HTS coils in Grenoble - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue IEEE Transactions on Applied Superconductivity Année : 2015

Performance tests of prototype high-field HTS coils in Grenoble

Résumé

Longitudinal and transverse quench propagation tests were performed at the Laboratoire National des Champs Magnetiques Intenses (LNCMI) high-field test facility on instrumented double pancake coils fabricated by CEA-Saclay using co-wound high-temperature superconductor (HTS) tapes. Energy deposited on an embedded heater initiated a quench and its subsequent propagations. Following the resulting thermomechanical analysis, a conductor design with stacked HTS tapes co-wound with stabilizers was conceived. A ten-turn demonstrator racetrack coil has been fabricated from the stacked HTS conductor with an aim to investigate the operation margin of an HTS coil in a background magnetic field misaligned from the coil axis as expected for the operating condition of an accelerator magnet insert. A test setup with a high current capacity up to 3 kA and angular variability that utilizes a room-temperature 376-mm-bore 10-T resistive magnet at LNCMI in Grenoble has been built. The performances and operation margin of the racetrack coil were investigated.
Fichier principal
Vignette du fichier
CERN-ACC-2014-0234.pdf (757.36 Ko) Télécharger le fichier

Dates et versions

hal-01147401 , version 1 (14-12-2023)

Identifiants

Citer

Yasuyuki Miyoshi, Arnaud Badel, Xavier Chaud, Tara Benkel, Benjamin Vincent, et al.. Performance tests of prototype high-field HTS coils in Grenoble. IEEE Transactions on Applied Superconductivity, 2015, 25 (3), pp.4600505. ⟨10.1109/TASC.2014.2363883⟩. ⟨hal-01147401⟩
140 Consultations
10 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More