Comparison of the strain field of abdominal aortic aneurysm measured by magnetic resonance imaging and stereovision: a feasibility study for prediction of the risk of rupture of aortic abdominal aneurysm

Résumé

The prediction of the risk of rupture of abdominal aortic aneurysm (AAA) is a complex problem. Currently the criteria to predict rupture of abdominal aortic aneurysms are aneurysm diameter and growth rates. It is generally believed that study of the wall strain distribution could be helpful to find a better decision criterion for surgery of aortic aneurysms before their rupture. The wall strain distribution depends on many biological and biomechanical factors such as elastic properties of the aorta, turbulent blood flow, anatomy of the aorta, presence of thrombus or not and so on. Recently, numerical simulations to estimate rupture-potential have received many attentions. However, none of the medical imaging tools for screening and monitoring of AAAs were studied in terms of mechanical behavior and experimentally to demonstrate their capability to measure relevant variables. The aim of this study was to develop a metrological approach for deployment testing of the ability of techniques for measuring local in-vitro deformations based on comparison of stereovision and MRI. In this paper, we present the implementation approach and results of the study based on cylindrical phantoms with or without AAA representing respectively healthy and unhealthy artery. Through this study, an experimental device was developed for the behavior study of AAA during a cardiac cycle. The results show that the stereovision techniques used in laboratory is well suited and is qualitatively and quantitatively equivalent with MRI measurements.
Fichier non déposé

Dates et versions

hal-01115789 , version 1 (11-02-2015)

Identifiants

Citer

Yufei Wang, David Joannic, Patrick Delassus, A. Lalande, Juillion Patrick, et al.. Comparison of the strain field of abdominal aortic aneurysm measured by magnetic resonance imaging and stereovision: a feasibility study for prediction of the risk of rupture of aortic abdominal aneurysm. Journal of Biomechanics, 2015, pp.1-7. ⟨10.1016/j.jbiomech.2015.01.017⟩. ⟨hal-01115789⟩
63 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More