Cardiac C-arm computed tomography using a 3D + time ROI reconstruction method with spatial and temporal regularization - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Medical Physics Année : 2014

Cardiac C-arm computed tomography using a 3D + time ROI reconstruction method with spatial and temporal regularization

Résumé

Purpose: Reconstruction of the beating heart in 3D + time in the catheter laboratory using only the available C-arm system would improve diagnosis, guidance, device sizing, and outcome control for intracardiac interventions, e.g., electrophysiology, valvular disease treatment, structural or congenital heart disease. To obtain such a reconstruction, the patient's electrocardiogram (ECG) must be recorded during the acquisition and used in the reconstruction. In this paper, the authors present a 4D reconstruction method aiming to reconstruct the heart from a single sweep 10 s acquisition. Method: The authors introduce the 4D RecOnstructiOn using Spatial and TEmporal Regularization (short 4D ROOSTER) method, which reconstructs all cardiac phases at once, as a 3D + time volume. The algorithm alternates between a reconstruction step based on conjugate gradient and four regularization steps: enforcing positivity, averaging along time outside a motion mask that contains the heart and vessels, 3D spatial total variation minimization, and 1D temporal total variation minimization. Results: 4D ROOSTER recovers the different temporal representations of a moving Shepp and Logan phantom, and outperforms both ECG-gated simultaneous algebraic reconstruction technique and prior image constrained compressed sensing on a clinical case. It generates 3D + time reconstructions with sharp edges which can be used, for example, to estimate the patient's left ventricular ejection fraction. Conclusions: 4D ROOSTER can be applied for human cardiac C-arm CT, and potentially in other dynamic tomography areas. It can easily be adapted to other problems as regularization is decoupled from projection and back projection. Acknowledgement: Published by the American Association of Physicists in Medicine. The electronic version of this work can be reached by using the following link: http://dx.doi.org/10.1118/1.4860215
Fichier non déposé

Dates et versions

hal-01097456 , version 1 (19-12-2014)

Identifiants

Citer

Cyril Mory, Vincent Auvray, Bo Zhang, Michael Grass, Dirk Schäfer, et al.. Cardiac C-arm computed tomography using a 3D + time ROI reconstruction method with spatial and temporal regularization. Medical Physics, 2014, 41 (2), pp.021903. ⟨10.1118/1.4860215⟩. ⟨hal-01097456⟩
111 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More