Background fluorescence reduction and absorption correction for fluorescence reflectance imaging - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2014

Background fluorescence reduction and absorption correction for fluorescence reflectance imaging

Résumé

Intraoperative fluorescence imaging in reflectance geometry (FRI) is an attractive imaging modality as it allows to noninvasively monitor the fluorescence targeted tumors located below the tissue surface. Some drawbacks of this technique are the background fluorescence decreasing the contrast and absorption heterogeneities leading to misinterpretations concerning fluorescence concentrations. We presented a FRI technique relying on a laser line scanning instead of a uniform illumination. Here, we propose a correction technique based on this illumination scheme. We scan the medium with the laser line and acquire at each position of the line both fluorescence and excitation images. We then use the finding that there is a relationship between the excitation intensity pro le and the background fluorescence one. This allows us to predict the amount of signal to subtract to the fluorescence images to get a better contrast. As the light absorption information is contained both in fluorescence and excitation images, this method also permits us to correct the eff ects of absorption heterogeneities, leading to a better accuracy for the detection. This technique has been validated on simulations (with a Monte-Carlo code and with the di usion approximation using NIRFAST) and experimentally with tissue-like liquid phantoms with di erent levels of background fluorescence. Fluorescent inclusions are observed in several con gurations at depths ranging from 1 mm to 1 cm. Results obtained with this technique are compared to those obtained with a more classical wide- field detection scheme for the contrast enhancement and to the fluorescence to excitation ratio approach for the absorption correction.
Fichier principal
Vignette du fichier
proceeding_bios_2014_v3.pdf (1.15 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00986388 , version 1 (06-05-2014)

Identifiants

Citer

Frédéric Fantoni, Lionel Herve, V. Poher, S. Gioux, Jerome I. Mars, et al.. Background fluorescence reduction and absorption correction for fluorescence reflectance imaging. BIOS2014, SPIE Photonics West, Feb 2014, San Francisco, United States. pp.8935-34, ⟨10.1117/12.2037600⟩. ⟨hal-00986388⟩
280 Consultations
405 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More