Experimental Investigations On The Effectiveness Of Electromagnetic Actuator As Sensor

Résumé

The study aims at examining the behavior of electromagnetic actuator as inductive sensor. The electromagnets are integrated in an alternative Wheatstone bridge and powered with alternative tension. This circuit allows the measurement of the electromagnet inductance variation, and as this variation is a function of the air gap, the displacement can be deduced. The effect of eddy currents is assessed in order to choose the suitable bridge frequency. Finally, a demodulator is used to obtain the tension proportional to the air gap value. The behavior is assessed experimentally. Experiments are carried out on a simple beam; clamped at one end and simply supported at the other. The displacements could be measured by using four eddy current sensors and the inductive sensor. The inductive sensor displacement and a modal approximation of the four eddy current sensors resulting from impact testing are compared. Analysis of the results obtained predicts an efficient and robust behavior.
Fichier non déposé

Dates et versions

hal-00946664 , version 1 (13-02-2014)

Identifiants

  • HAL Id : hal-00946664 , version 1

Citer

Benjamin Defoy, Thomas Ge Oil&gas Thermodyn Alban, Jarir Mahfoud. Experimental Investigations On The Effectiveness Of Electromagnetic Actuator As Sensor. XVIII Symposium On Vibrations, Shocks And Noise VCB2012, 2012, France. pp.1-7. ⟨hal-00946664⟩