Pulse-tube dilution refrigeration below 10 mK for Astrophysics - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Journal of Low Temperature Physics Année : 2008

Pulse-tube dilution refrigeration below 10 mK for Astrophysics

Résumé

Astroparticle bolometric detectors often rely on the use of dilution refrigerators providing a large cooling power at millikelvin temperatures. Conventional machines, however, need a systematic supply of cryogenic fluids, complicating and making more expensive their operation, particularly in underground laboratories. We describe here novel cryogen-free dilution units, able to cool down large detectors to millikelvin temperatures, and where cooling and warming times have been optimised.
Fichier principal
Vignette du fichier
JLTP_151_640-644_2008.pdf (174.51 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00921380 , version 1 (20-12-2013)

Identifiants

Citer

Thomas Prouvé, Henri Godfrin, Christian Gianese, Sebastien Triqueneaux, Alain Ravex. Pulse-tube dilution refrigeration below 10 mK for Astrophysics. Journal of Low Temperature Physics, 2008, 151, pp.640-644. ⟨10.1007/s10909-008-9725-6⟩. ⟨hal-00921380⟩