Influence of control strategy on the global efficiency of a Direct Wave Energy Converter with electric Power Take-Off - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2013

Influence of control strategy on the global efficiency of a Direct Wave Energy Converter with electric Power Take-Off

Résumé

The choice of control strategy for Direct Wave Energy Converters (DWEC) is often discussed without taking into account the limitations of electric Power Take-Off (PTO): limits of torque or force and power, as well as losses in the electric chain. These assumptions leads to large and expensive electric systems, that prevent leading to a global minimization of the per-kWh cost. We propose herein a simple loss model in order to design a better control strategy.
Fichier principal
Vignette du fichier
EVER13-paper-130-HAL.pdf (1000.02 Ko) Télécharger le fichier
presentation_HAL.pdf (3.44 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Format : Autre

Dates et versions

hal-00831687 , version 1 (07-06-2013)
hal-00831687 , version 2 (11-09-2014)

Identifiants

Citer

Thibaut Kovaltchouk, Bernard Multon, Hamid Ben Hamed, Judicael Aubry, François Rongère, et al.. Influence of control strategy on the global efficiency of a Direct Wave Energy Converter with electric Power Take-Off. Ecological Vehicles and Renewable Energies (EVER), 2013 8th International Conference and Exhibition on, Mar 2013, Monaco, France. ⟨10.1109/EVER.2013.6521543⟩. ⟨hal-00831687v1⟩
543 Consultations
524 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More