Image Denoising in Mixed Poisson–Gaussian Noise, IEEE Transactions on Image Processing, vol.20, issue.3, pp.696-708, 2011. ,
DOI : 10.1109/TIP.2010.2073477
The study of an iterative method for the reconstruction of images corrupted by Poisson and Gaussian noise, Inverse Problems, vol.24, issue.20, p.pp, 2008. ,
Image calibration in fluorescence microscopy, Journal of Microscopy, vol.216, issue.1, pp.15-24, 2004. ,
DOI : 10.1111/j.0022-2720.2004.01390.x
Sources of noise in three-dimensional microscopical data sets, " in Three-Dimensional Confocal Microscopy: Volume Investigation of Biological Specimens, pp.47-94, 1994. ,
Automatic tracking of individual fluorescence particles: application to the study of chromosome dynamics, IEEE Transactions on Image Processing, vol.14, issue.9, pp.1372-1383, 2005. ,
DOI : 10.1109/TIP.2005.852787
Fluorescence microscopy imaging denoising with log-Euclidean priors and photobleaching compensation, 2009 16th IEEE International Conference on Image Processing (ICIP), pp.809-812, 2009. ,
DOI : 10.1109/ICIP.2009.5414440
ContributionsàContributions`Contributionsà la microscopiè a fluorescence en imagerie biologique : modélisation de la PSF, restauration d'images et détection super-résolutive, 2007. ,
Precision of light intensity measurement in biological optical microscopy, Journal of Microscopy, vol.69, issue.7, pp.163-174, 2007. ,
DOI : 10.1111/j.0022-2720.2004.01390.x
Multiframe sure-let denoising of timelapse fluorescence microscopy images, 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, pp.149-152, 2008. ,
DOI : 10.1109/ISBI.2008.4540954
Non-parametric regression for patch-based fluorescence microscopy image sequence denoising, 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, pp.748-751, 2008. ,
DOI : 10.1109/ISBI.2008.4541104
URL : https://hal.archives-ouvertes.fr/inria-00322321
Automatic noise quantification for confocal fluorescence microscopy images, Computerized Medical Imaging and Graphics, vol.34, issue.6, pp.426-434, 2010. ,
DOI : 10.1016/j.compmedimag.2010.04.001
Method of calibration of a fluorescence microscope for quantitative studies, Journal of Microscopy, vol.231, issue.1, pp.101-111, 2011. ,
DOI : 10.1111/j.1365-2818.2011.03514.x
An EM approach for Poisson-Gaussian noise modeling, European Signal Processing Conference (EUSIPCO), pp.2244-2248, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00733633
Wavefront sensing for aberration modeling in fluorescence macroscopy, 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro, pp.905-908, 2011. ,
DOI : 10.1109/ISBI.2011.5872550
URL : https://hal.archives-ouvertes.fr/inria-00563988
Photobleaching correction in fluorescence microscopy images, Journal of Physics: Conference Series, vol.90, issue.8, p.pp, 2007. ,
DOI : 10.1088/1742-6596/90/1/012068
Nonexponential statistics of fluorescence photobleaching, The Journal of Chemical Physics, vol.121, issue.7, pp.2899-2903, 2004. ,
DOI : 10.1063/1.1773162
Photobleaching kinetics of fluorescein in quantitative fluorescence microscopy, Biophysical Journal, vol.68, issue.6, pp.2588-2600, 1995. ,
DOI : 10.1016/S0006-3495(95)80442-X
Choosing starting values for the EM algorithm for getting the highest likelihood in multivariate Gaussian mixture models, Computational Statistics & Data Analysis, vol.41, issue.3-4, pp.3-4, 2003. ,
DOI : 10.1016/S0167-9473(02)00163-9
An empirical comparison of EM initialization methods and model choice criteria for mixtures of skew-normal distributions, 19 SINAPE -Simpósio Nacional de Probabilidade e Estatística, 2010. ,
A Variable Initialization Approach to the EM Algorithm for Better Estimation of the Parameters of Hidden Markov Model Based Acoustic Modeling of Speech Signals, Advances in Data Mining. Applications in Medicine, Web Mining, Marketing, Image and Signal Mining, pp.416-430, 1007. ,
DOI : 10.1007/11790853_33
Convergence Properties of the Nelder--Mead Simplex Method in Low Dimensions, SIAM Journal on Optimization, vol.9, issue.1, pp.112-147, 1998. ,
DOI : 10.1137/S1052623496303470
On Halley's Iteration Method, The American Mathematical Monthly, vol.92, issue.2, pp.131-134, 1985. ,
DOI : 10.2307/2322644
Photostability of xanthene molecules trapped in poly(vinyl alcohol) (PVA) matrices, Journal of Photochemistry and Photobiology A: Chemistry, vol.120, issue.2, pp.141-149, 1999. ,
DOI : 10.1016/S1010-6030(98)00416-X