Medical robotics in computer-integrated surgery, IEEE Transactions on Robotics and Automation, vol.19, issue.5, pp.765-781, 2003. ,
DOI : 10.1109/TRA.2003.817058
A dexterous system for laryngeal surgery-multibackbone bending snake-like slaves for teleoperated dexterous surgical tool manipulation, IEEE International Conference on Robotics and Automation, pp.351-357, 2004. ,
Mechanics of Precurved-Tube Continuum Robots, IEEE Transactions on Robotics, vol.25, issue.1, pp.67-78, 2009. ,
DOI : 10.1109/TRO.2008.2006868
A Flexible, Tendon-Controlled Device for Endoscopy, The International Journal of Robotics Research, vol.6, issue.7, pp.121-131, 1993. ,
DOI : 10.1177/027836499301200202
Micro active catheter system with multi degrees of freedom, Proceedings of the 1994 IEEE International Conference on Robotics and Automation, pp.2290-2295, 1994. ,
DOI : 10.1109/ROBOT.1994.350944
Automation of colonoscopy. II. Visual control aspects, IEEE Engineering in Medicine and Biology Magazine, vol.17, issue.3, pp.81-89, 1998. ,
DOI : 10.1109/51.677173
Shape memory alloy servo actuator system with electric resistance feedback and application for active endoscope, Proceedings. 1988 IEEE International Conference on Robotics and Automation, pp.427-430, 1988. ,
DOI : 10.1109/ROBOT.1988.12085
The development of a robot endoscope, Proc. of the IEEE-RSJ Int. Conf. on Intelligent Robots and Systems, pp.3315-3320, 1995. ,
A miniature steerable end-effector for application in an integrated system for computer-assisted arthroscopy, Proceedings of International Conference on Robotics and Automation, pp.1573-1579, 1997. ,
DOI : 10.1109/ROBOT.1997.614364
Robotic solutions and mechanisms for a semi-autonomous endoscope, IEEE/RSJ International Conference on Intelligent Robots and System, pp.1379-1384, 2002. ,
DOI : 10.1109/IRDS.2002.1043947
Design of a vision-guided microrobotic colonoscopy system, Advanced Robotics, vol.18, issue.2, pp.87-114, 2000. ,
DOI : 10.1163/156855300741465
Review of locomotion techniques for robotic colonoscopy, Proceedings of the International Conference on Robotics and Automation, pp.1086-1091, 2003. ,
Design of an advanced tool guiding system for robotic surgery, 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422), pp.2651-2656, 2003. ,
DOI : 10.1109/ROBOT.2003.1241993
Inchworm-Like Colonoscopic Robot with Hollow Body and Steering Device, JSME International Journal Series C, vol.49, issue.1, pp.205-212, 2006. ,
DOI : 10.1299/jsmec.49.205
Shape memory alloy clamping devices of a capsule for monitoring tasks in the gastrointestinal tract, Journal of Micromechanics and Microengineering, vol.15, issue.11, pp.2045-2055, 2005. ,
DOI : 10.1088/0960-1317/15/11/008
A Novel SMA-Based Actuator for a Legged Endoscopic Capsule, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006., 2006. ,
DOI : 10.1109/BIOROB.2006.1639128
Design and Fabrication of a Locomotive Mechanism for Capsule-Type Endoscopes Using Shape Memory Alloys (SMAs), IEEE/ASME Transactions on Mechatronics, vol.10, issue.1, pp.77-86, 2005. ,
DOI : 10.1109/TMECH.2004.842222
A Legged Anchoring Mechanism for Capsule Endoscopes Using Micropatterned Adhesives, IEEE Transactions on Biomedical Engineering, vol.55, issue.12, pp.2759-2767, 2008. ,
DOI : 10.1109/TBME.2008.2002111
Continuum robots - a state of the art, Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C), pp.2849-2853, 1999. ,
DOI : 10.1109/ROBOT.1999.774029
The AMADEUS dextrous subsea hand: design, modeling, and sensor processing, IEEE Journal of Oceanic Engineering, vol.24, issue.1, pp.96-111, 1999. ,
DOI : 10.1109/48.740158
The KSI tentacle manipulator, Proceedings of 1995 IEEE International Conference on Robotics and Automation, pp.3149-3154, 1995. ,
DOI : 10.1109/ROBOT.1995.525733
Modeling and Control of a Hybrid Continuum Active Catheter for Aortic Aneurysm Treatment, Proceedings of the 2005 IEEE International Conference on Robotics and Automation, pp.924-929, 2005. ,
DOI : 10.1109/ROBOT.2005.1570235
Development and kinematic analysis of a silicone-rubber bending tip for colonoscopy, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems, pp.168-173, 2006. ,
DOI : 10.1109/IROS.2006.282129
URL : https://hal.archives-ouvertes.fr/hal-00402450
Applying a flexible microactuator to robotic mechanisms, IEEE Control Systems, vol.12, issue.1, pp.21-27, 1992. ,
DOI : 10.1109/37.120448
Modélisation, simulation et commande d'une servovalve electropneumatique, 1996. ,
A more reliable electrohydraulic servovalve, Robot VI Conference, 1982. ,
Design and control of an actuator for colonoscopy, 6th International Workshop on Research and Education in Mechatronic, pp.109-114, 2005. ,
Design of slim slime robot and its gait of locomotion, Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium (Cat. No.01CH37180), pp.707-715, 2001. ,
DOI : 10.1109/IROS.2001.976252
Kinematics for multisection continuum robots, IEEE Transactions on Robotics, vol.22, issue.1, pp.43-55, 2006. ,
DOI : 10.1109/TRO.2005.861458
Sensor-based guidance control of a continuum robot for a semi-autonomous colonoscopy, Robotics and Autonomous Systems, vol.57, issue.6-7, pp.712-722, 2008. ,
DOI : 10.1016/j.robot.2008.11.001
URL : https://hal.archives-ouvertes.fr/hal-00368865
Resolved Motion Rate Control of Manipulators and Human Prostheses, IEEE Transactions on Man Machine Systems, vol.10, issue.2, pp.47-53, 1969. ,
DOI : 10.1109/TMMS.1969.299896
Redundancy resolution of manipulator through torque optimization, A.I, Massachussett Institute of Technology, vol.882, 1986. ,
Advanced robotics, Redundancy and Optimization, 1991. ,