Irradiation creep of SA 304L and CW 316 stainless steels: Mechanical behaviour and microstructural aspects. Part II: Numerical simulation and test of SIPA model
Résumé
A cluster dynamic model has been adapted to test the Stress Induced Preferential Absorption of Defect (SIPA) on Frank loops hypothesis concerning irradiation creep, to reproduce quantitatively both microstructure evolution and its stress induced anisotropy and macroscopic creep rate. It is concluded that SIPA on Frank loops model can account for the observed defects structure, but is unable to reproduce quantitatively the creep rate. (C) 2011 Elsevier B.V. All rights reserved.