.. Rappels-mécaniques-et-notation, 52 2.5.1 Rappels sur la mécanique des Milieux Continus, p.59

.. Une-modélisation-proche-de-la-réalité-anatomique, 73 3.2.1 Définition des conditions limites, p.74

.. Étude-des-paramètres-de-convergence, 81 3.4.1 Gestion des grandes déformations, p.83

M. Amarani, F. Jaillet, and B. Shariat, Deformable objects modeling and animation : Application to organs' interactions simulation, Journal for Geometry and Graphics, vol.4, issue.2, pp.181-182, 2000.

I. Amidror, Scattered data interpolation methods for electronic imaging systems: a survey, Journal of Electronic Imaging, vol.11, issue.2, pp.157-176, 2002.
DOI : 10.1117/1.1455013

V. Baudet, Modélisation et simulation paramétrable d'objets déformable, Application au traitement des cancers pulmonaires, 2006.

A. Bouchet and J. Cuilleret, Anatomie : topographie, descriptive et fonctionnelle, Simep, vol.12, p.180, 1974.

. L. Bdz-+-99-]-m, J. Bahner, A. Debus, S. Zabel, G. Levegrun et al., Digitally reconstructed radiographs from abdominal CT scans as a new tool for radiotherapy planning, Invest. Radiol, vol.34, issue.7, p.643, 1999.

I. Ross, . Berbeco, B. Steve, . Jiang, C. Gregory et al., Integrated radiotherapy imaging system (iris) : design considerations of tumour tracking with linac gantry-mounted diagnostic xray systems with flat-panel detectors, Physics in Medicine and Biology, vol.49, issue.2, pp.243-255, 2004.

M. Bro-nielsen, Surgery Simulation using Fast Finite Elements, VBC '96 : Proceedings of the 4th International Conference on Visualization in Biomedical Computing, pp.529-534, 1996.
DOI : 10.1007/BFb0046994

. [. Bro-nielsen, Finite element modeling in surgery simulation, Proceedings of the IEEE, vol.86, issue.3, pp.490-503, 1998.
DOI : 10.1109/5.662874

I. Ross, T. Berbeco, E. Neicu, . Rietzel, T. George et al., A technique for respiratory-gated radiotherapy treatment verification with an epid in cine mode, Physics in Medicine and Biology, vol.50, issue.16, pp.3669-3679, 2005.

. E. Bpm-+-95-]-s, E. Benzley, K. Perry, B. Merkle, G. D. Clark et al., A comparison of all hexagonal and all tetrahedral finite element meshesfor elastic and elastoplastic analysis, Proceedings, 4th annual international meshing roundtable, pp.179-191, 1995.

. Bsd-+-05-]-kk, M. Brock, L. Sharpe, S. Dawson, D. Kim et al., Accuracy of finite element model-based multi-organ deformable image registration, Medical physics, vol.32, issue.6, pp.1647-59, 2005.

M. Cani, Introduction to implicit surfaces, chapter Physically based animation, Jules Bloomenthal, 1997.

F. Ivan, R. Costa, and . Balaniuk, Lem -an approach for real time physically based soft tissue simulation, ICRA, pp.2337-2343, 2001.

H. [. Cotin, N. Delingette, and . Ayache, Real time volumetric deformable models for surgery simulation, Visualization in Biomedical Computing, Proceedings, volume 1131 of Lecture Notes in Computer Science, 1996.
DOI : 10.1007/BFb0046995

URL : https://hal.archives-ouvertes.fr/inria-00615771

[. Crum, T. Hartkens, and D. Hill, Non-rigid image registration: theory and practice, The British Journal of Radiology, vol.77, issue.suppl_2, pp.140-153, 2004.
DOI : 10.1259/bjr/25329214

[. Chi, J. Liang, and D. Yan, A material sensitivity study on the accuracy of deformable organ registration using linear biomechanical modelsa), Medical Physics, vol.19, issue.2, pp.421-433, 2006.
DOI : 10.1109/42.796284

. J. Cmn-+-02-]-i, J. M. Chetty, T. S. Moran, D. L. Nurushev, B. A. Mcshan et al., Experimental validation of the DPM Monte Carlo code using minimally scattered electron beams in heterogeneous media, Phys. Med. Biol, vol.47, pp.1837-1851, 2002.

]. S. Cot97 and . Cotin, Modèles anatomiques déformables en temps réel : Application à la simulation de chirurgie avec retour d'effort, 1997.

J. [. Cullip, J. G. Symons, E. L. Rosenman, and . Chaney, Digitally reconstructed fluoroscopy and other interactive volume visualisations in 3-D treatment planning, Int J Radiat Oncol Biol Phys, issue.51, p.27145, 1993.

M. Cappello and A. De-troyer, Role of rib cage elastance in the coupling between the abdominal muscles and the lung, Journal of Applied Physiology, vol.97, issue.1, pp.85-90, 2004.
DOI : 10.1152/japplphysiol.00032.2004

. L. Ctt-+-95-]-e, J. S. Chaney, G. Thorn, T. Tracton, J. G. Cullip et al., A portable software tool for computing digitally reconstructed radiographs, Int. J. Radiat. Oncol. Biol. Phys, vol.32, issue.7, p.491, 1995.

]. H. Dca99a, S. Delingette, N. Cotin, and . Ayache, Efficient linear elastic models of soft tissues for real time surgery simulation, Medecine Meets Virtual Reality VII, pp.139-151, 1999.

H. Delingette, S. Cotin, and N. Ayache, Efficient linear elastic models of soft tissues for real time surgery simulation, Medecine Meets Virtual Reality VII, Interactive Technology and the New Paradigm for He althcare, pp.139-151, 1999.
URL : https://hal.archives-ouvertes.fr/inria-00073174

G. Debunne, M. Desbrun, M. Cani, and A. H. Barr, Dynamic real-time deformations using space & time adaptive sampling, Proceedings of the 28th annual conference on Computer graphics and interactive techniques , SIGGRAPH '01, 2001.
DOI : 10.1145/383259.383262

URL : https://hal.archives-ouvertes.fr/inria-00510045

A. Davies, . Hill, . Holmes, P. Halliwell, and . Jackson, Ultrasound quantitation of respiratory organ motion in the upper abdomen, The British Journal of Radiology, vol.67, issue.803, pp.1096-1102, 1994.
DOI : 10.1259/0007-1285-67-803-1096

A. Deguet, A. Joukhadar, and C. Laugier, Models and algorithms for the collision of rigid and deformable bodies, WAFR '98 : Proceedings of the third workshop on the algorithmic foundations of robotics on Robotics, p.142
URL : https://hal.archives-ouvertes.fr/inria-00073113

. Bibliographie-algorithmic-perspective, Algorithme de contraintes actives appliquées au contact unilatéral, pp.327-338, 1993.

E. [. Schroter and . Denny, A model of non-uniform lung parenchyma distorsion, J. of Biomechanics, 2005.

A. [. Escolar and . Escolar, Lung hysteresis : a morphological view, Histology and histopathology, vol.19, pp.159-166, 2004.

[. Fitzpatrick and J. West, The distribution of target registration error in rigid-body point-based registration, IEEE Transactions on Medical Imaging, vol.20, issue.9, pp.917-927, 2001.
DOI : 10.1109/42.952729

[. Van-gelder, Approximate simulation of elastic membranes by triangulated spring meshes. journal of graphics tools, pp.21-41, 1998.

. P. Grr-+-02-]-j, J. Gerard, J. Remillieux, M. Rochat, J. Bajard et al., Etoile : Rhone-alpes project for carbon-ion treatment of radioresistant tumours. Revue-de-l'Electricite-et-del'Electronique, pp.77-80, 2002.

J. M. Gavin, C. Sims, G. Donminiak, and J. S. Cooper, The use of digitally reconstructed radiographs for three-dimensional treatment planning and CT-simulation

F. Sarah, J. Frisken-gibson, A. Samosky, C. Mor, W. Fyock et al., Simulating arthroscopic knee surgery using volumetric object representations, real-time volume rendering and haptic feedback, CVRMed-MRCAS '97 : Proceedings of the First Joint Conference on Computer Vision, Virtual Reality and Robotics in Medicine and Medial Robotics and Computer-Assisted Surgery, pp.369-378, 1997.

[. G. T80-]-g and . Herman, Image Reconstruction from Projections, 1980.

A. [. Grimal, S. Watzky, and . Naili, Nonpenetrating impact on the thorax : a study of the wave propagation, Comptes Rendus de l'Académie des Sciences, pp.655-662, 2001.

H. Shirato, K. Suzuki, G. Sharp, K. Fujita, R. Onimaru et al., Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy, International Journal of Radiation Oncology*Biology*Physics, vol.64, issue.4, pp.1229-1235, 2006.
DOI : 10.1016/j.ijrobp.2005.11.016

]. A. Hme-+-05, N. R. Hsu, P. M. Miller, J. C. Evans, S. Bamber et al., Feasibility of using ultrasound for real-time tracking during radiotherapy, Medical Physics, vol.32, issue.6, pp.1500-1512, 2005.

H. Shirato, S. Shimizu, K. Kitamura, T. Nishioka, K. Kagei et al., Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor, International Journal of Radiation Oncology*Biology*Physics, vol.48, issue.2, pp.2000-143
DOI : 10.1016/S0360-3016(00)00625-8

J. Humphrey, A possible role of the pleura in lung mechanics, Journal of Biomechanics, vol.20, issue.8, pp.773-777, 1987.
DOI : 10.1016/0021-9290(87)90056-X

M. A. Hajji, T. A. Wilson, and S. J. Lai-fook, Improved measurements of shear modulus and pleural membrane tension of the lung, J Appl Physiol, vol.47, issue.1, pp.175-181, 1979.

J. Balter, K. Lam, C. Mcginn, T. Lawrence, T. Haken et al., Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging, International Journal of Radiation Oncology*Biology*Physics, vol.41, issue.4, 1998.
DOI : 10.1016/S0360-3016(98)00130-8

D. [. James and . Pai, art defo -accurate real time deformable objects, In Computer Graphics (ACM SIGGRAPH), 1999.

J. Rodarte, Importance of lung material properties in respiratory system mechanics . The Physiologist, pp.21-26, 1977.

D. [. Kaye, F. P. Metaxas, and . Primiano, A 3D virtual environment for modeling mechanical cardiopulmonary interactions, National Library of Medicine and the Philadelphia VAMC, pp.1-4, 1998.
DOI : 10.1007/BFb0029260

P. Keall, . Starkschall, K. Shukla, . Forster, C. Ortiz et al., Acquiring 4D thoracic CT scans using a multislice helical method, Physics in Medicine and Biology, vol.49, issue.10, pp.492053-2067, 2004.
DOI : 10.1088/0031-9155/49/10/015

H. [. Lorensen and . Cline, Marching cubes: A high resolution 3D surface construction algorithm, ACM SIGGRAPH Computer Graphics, vol.21, issue.4, pp.163-169, 1987.
DOI : 10.1145/37402.37422

[. Lai-fook, Lung parenchyma described as a prestressed compressible material, Journal of Biomechanics, vol.10, issue.5-6
DOI : 10.1016/0021-9290(77)90008-2

D. [. Langen and . Jones, Organ motion and its management, International Journal of Radiation Oncology*Biology*Physics, vol.50, issue.1, pp.265-278, 2001.
DOI : 10.1016/S0360-3016(01)01453-5

[. Lambert and T. Wilson, A model for the elastic properties of the lung and their effect of expiratory flow, J Appl Physiol, vol.34, pp.34-48, 1973.

. Mbg-+-00-]-n, D. Milickovic, S. Baltas, M. Giannouli, N. Lahanas et al., CT imaging based digitally reconstructed radiographs and their application in brachytherapy, Physics in Medicine and Biology, vol.45, pp.2787-2800, 2000.

C. Muller, M. Beuve, and B. Shariat, Modelling of deformable objects with particle systems : influence of the applied potential, 9th workshop on Heavy Charged Particles in Biology and Medicine, p.32, 2003.

B. Mirtich and J. F. Canny, Impulse-based simulation of rigid bodies, Proceedings of the 1995 symposium on Interactive 3D graphics , SI3D '95, pp.181-188, 1995.
DOI : 10.1145/199404.199436

J. Meadmil01 and ]. K. Miller, Mechanical properties of lungs How to test very soft biological tissues in extension, Physiol. Rev. Journal of Biomechanics, vol.41, issue.345, pp.281-328651, 1961.

]. K. Mil05 and . Miller, Method of testing very soft biological tissues in compression, Journal of Biomechanics, vol.38, issue.1, pp.153-158, 2005.

M. Marchal, E. Promayon, and J. Troccaz, Simulating Complex Organ Interactions: Evaluation of a Soft Tissue Discrete Model, ISVC, pp.175-182
DOI : 10.1007/11595755_22

URL : https://hal.archives-ouvertes.fr/hal-00204871

M. Magnenat-thalmann, F. Cordier, M. Keckeisen, S. Kimmerle, R. Klein et al., Simulation of clothes for real-time applications, Eurographics 2004, Tutorials 1 : Simulation of Clothes for Real-time Applications. INRIA and the Eurographics Association, 2004.

D. [. Nedel and . Thalmann, Real time muscle deformations using mass-spring systems, Proceedings. Computer Graphics International (Cat. No.98EX149), p.156, 1998.
DOI : 10.1109/CGI.1998.694263

F. James, J. K. O-'brien, and . Hodgins, Graphical modeling and animation of brittle fracture, Proceedings of SIGGRAPH 99, pp.137-146, 1999.

M. [. Owen and . Lewis, The mechanics of lung tissue under high-frequency ventilation, SIAM Journal on Applied Mathematics, issue.5, pp.611731-1761, 2001.

P. Keall, A. Todor, S. Vedam, C. Bartee, J. Siebers et al., On the use of EPID-based implanted marker tracking for 4D radiotherapy, Medical Physics, vol.55, issue.3, pp.313492-3499, 2004.
DOI : 10.1118/1.1812608

T. [. Pan, E. Lee, G. Rietzel, and . Chen, 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT, Pod05] E. B. Podgorsak. Radiation Oncology Physics : A Handbook for Teachers and Students. IAEA, pp.333-340, 2004.
DOI : 10.1118/1.1639993

]. E. Pro97 and . Promayon, Modelling and simulation of the respiration, 1997.

]. J. [-rad17 and . Radon, Über die bestimmung von funktionen durch ihre integralwerte längs ge-wisser mannigfaltigkeiten, Mathematisch-PhysikalischeKlasse, vol.69, issue.77, 1917.

E. Rietzel, G. Chen, N. Choi, and C. Willet, Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion, International Journal of Radiation Oncology*Biology*Physics, vol.61, issue.5, pp.611535-50, 2005.
DOI : 10.1016/j.ijrobp.2004.11.037

T. William and . Reeves, Particle systems a technique for modeling a class of fuzzy objects, SIGGRAPH '83 : Proceedings of the 10th annual conference on Computer graphics and interactive techniques, pp.359-375, 1983.

R. Tai and G. Lee, Isotropy and homogeneity of lung tissue deformation, Journal of Biomechanics, vol.14, issue.4, pp.243-52, 1981.
DOI : 10.1016/0021-9290(81)90069-5

D. C. Ruspini, K. Kolarov, and O. Khatib, The haptic display of complex graphical environments, Proceedings of the 24th annual conference on Computer graphics and interactive techniques , SIGGRAPH '97, pp.31345-352, 1997.
DOI : 10.1145/258734.258878

[. Rohrer, Ueber die topographische verteilung der elastischen eigenschaften in der lunge, Schweis. Med. Wochschr, vol.5, issue.1, pp.740-741, 1921.

F. [. Kowe, R. C. Matthews, D. Schroter, and . Hitchings, Analysis of elastic and surface tension effects in the lung alveolus using finite element methods, Journal of Biomechanics, vol.19, issue.7, pp.541-549, 1986.
DOI : 10.1016/0021-9290(86)90127-2

D. [. Rit, C. Sarrut, and . Ginestet, Respiratory signal extraction for 4d ct imaging of the thorax from cone-beam ct projections, MICCAI 3D reconstruction in radiotherapy planning. Radiologie, pp.556-563, 1991.
URL : https://hal.archives-ouvertes.fr/hal-01505986

[. Sharp, S. Jiang, S. Shimizu, and H. Shirato, Prediction of respiratory tumour motion for real-time image-guided radiotherapy, Physics in Medicine and Biology, vol.49, issue.3, pp.425-440, 2004.
DOI : 10.1088/0031-9155/49/3/006

C. [. Simo and . Miehe, Associative coupled thermoplasticity at finite strains: Formulation, numerical analysis and implementation, Computer Methods in Applied Mechanics and Engineering, vol.98, issue.1, pp.41-104, 1992.
DOI : 10.1016/0045-7825(92)90170-O

K. [. Sherouse, E. L. Novins, and . Chaney, Computation of digitally reconstructed radiographs for use in radiotherapy treatment design, International Journal of Radiation Oncology*Biology*Physics, vol.18, issue.3, p.18651, 1990.
DOI : 10.1016/0360-3016(90)90074-T

W. Thomas, S. R. Sederberg, and . Parry, Free-form deformation of solid geometric models, SIGGRAPH '86 : Proceedings of the 13th annual conference on Computer graphics and interactive techniques, pp.151-160, 1986.

]. D. Sta84 and . Stamenovic, Mechanical properties of pleural membrane, J Appl Physiol, vol.57, issue.4, pp.1189-1194, 1984.

D. Terzopoulos, J. Platt, A. Barr, and K. Fleischer, Elastically deformable models, SIGGRAPH '87 : Proceedings of the 14th annual conference on Computer graphics and interactive techniques, pp.205-214, 1987.
DOI : 10.1145/37401.37427

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.324.2890

]. J. Tuk77 and . Tukey, Exploratory Data Analysis, 1977.

U. Meier, O. Lopez, C. Monserrat, M. Juan, and A. M. , Real-time deformable models for surgery simulation: a survey, Computer Methods and Programs in Biomedicine, vol.77, issue.3, pp.183-97, 2005.
DOI : 10.1016/j.cmpb.2004.11.002

V. Cano and E. Lorentz, Introduction dans le code aster d'un modèle de comportement en grandes déformations élastoplastiques avec écrouissage isotrope, 1998.

Y. [. Vawter, J. B. Fung, and . West, Constitutive Equation of Lung Tissue Elasticity, Journal of Biomechanical Engineering, vol.101, issue.1, pp.38-45, 1979.
DOI : 10.1115/1.3426222

[. Vongphouthone, Estimation du volume pulmonaire dans des images 3d, 2003.

]. J. Wa99 and . Wong, The use of active breathing control (ABC) to reduce margin for breathing motion, Int. J. Radiation Oncology Biol. Phys, vol.44, issue.4, pp.911-919, 1999.

F. [. West and . Matthews, Stresses, strains, and surface pressures in the lung caused by its weight, J. Appl. Physiol, vol.32, pp.332-345, 1972.

K. [. Yang and . Wang, Finite element modeling of the human thorax. The Second Visible Human Project Conference, 1998.

J. [. Zitova and . Flusser, Image registration methods: a survey, Image and Vision Computing, vol.21, issue.11, pp.977-1000146, 2003.
DOI : 10.1016/S0262-8856(03)00137-9