Real-Time Respiratory Motion Correction for Cardiac Electrophysiology Procedures Using Image-Based Coronary Sinus Catheter Tracking - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2010

Real-Time Respiratory Motion Correction for Cardiac Electrophysiology Procedures Using Image-Based Coronary Sinus Catheter Tracking

Résumé

X-ray fluoroscopically guided cardiac electrophysiological procedures are routinely carried out for diagnosis and treatment of cardiac arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of static 3D roadmaps derived from pre-procedural volumetric data can be used to add anatomical information. However, the registration between the 3D roadmap and the 2D X-ray data can be compromised by patient respiratory motion. We propose a novel method to correct for respiratory motion using real-time image-based coronary sinus (CS) catheter tracking. The first step of the proposed technique is to use a blob detection method to detect all possible catheter electrodes in the X-ray data. We then compute a cost function to select one CS catheter from all catheter-like objects. For correcting respiratory motion, we apply a low pass filter to the 2D motion of the CS catheter and update the 3D roadmap using this filtered motion. We tested our CS catheter tracking method on 1048 fluoroscopy frames from 15 patients and achieved a success rate of 99.3% and an average 2D tracking error of 0.4 mm ± 0.2 mm. We also validated our respiratory motion correction strategy by computing the 2D target registration error (TRE) at the pulmonary veins and achieved a TRE of 1.6 mm ± 0.9 mm. Copyright Springer-Verlag 2010. The original publication is available at www.springerlink.com (use http://www.springerlink.com/content/979h530257v45663/ or doi)
Fichier principal
Vignette du fichier
Gogin_MICCAI10.pdf (154.91 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00595036 , version 1 (23-11-2011)

Identifiants

Citer

Yingliang Ma, Andy P. King, Nicolas Gogin, Aldo Rinaldi, J. Gill, et al.. Real-Time Respiratory Motion Correction for Cardiac Electrophysiology Procedures Using Image-Based Coronary Sinus Catheter Tracking. Medical Image Computing and Computer-Assisted Intervention Conference (MICCAI), Sep 2010, Beijing, China. pp.391--399, ⟨10.1007/978-3-642-15705-9_48⟩. ⟨hal-00595036⟩
43 Consultations
261 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More