Computer assisted planning and orbital surgery : partient-related prediction of osteotomy size in proptosis reduction - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Clinical Biomechanics Année : 2005

Computer assisted planning and orbital surgery : partient-related prediction of osteotomy size in proptosis reduction

V. Luboz
  • Fonction : Auteur
P. Swider
  • Fonction : Auteur
F. Boutault
  • Fonction : Auteur
Yohan Payan

Résumé

Proptosis is characterized by a protrusion of the eyeball due to an increase of the orbital tissue volume. To recover a normal eyeball positioning, the most frequent surgical technique consists in the osteotomy of orbital walls combined with the manual loading on the eyeball. Only a rough clinical rule is currently available for the surgeons but it is useless for this technique. The first biomechanical model dealing with proptosis reduction, validated in one patient, has been previously proposed by the authors. Methods. This paper proposes a rule improving the pre-operative planning of the osteotomy size in proptosis reduction. Patient-related poroelastic finite element models combined with sensitivity studies were used to propose two clinical rules to improve the pre-operative planning of proptosis reduction. This poroelastic model was run on 12 patients. Sensitivity studies permitted to establish relationships between the osteotomy size, the patient-related orbital volume, the decompressed tissue volume and the eyeball back- ward displacement. Findings. The eyeball displacement and the osteotomy size were non-linearly related: an exponential rule has been proposed. The patient-related orbital volume showed a significant influence: a bi-quadratic analytical equation liking the osteotomy size, the orbital volume and the targeted eyeball protrusion has been established. Interpretation. Two process rules derived from patient-related biomechanical FE models have been proposed for the proptosis reduction planning. The implementation of the process rules into a clinical setting is easy since only a sagittal radiography is required. The osteotomy size can be monitored using optical guided instruments.

Dates et versions

hal-00583066 , version 1 (04-04-2011)

Identifiants

Citer

V. Luboz, Dominique Ambard, P. Swider, F. Boutault, Yohan Payan. Computer assisted planning and orbital surgery : partient-related prediction of osteotomy size in proptosis reduction. Clinical Biomechanics, 2005, 20 (9), pp.900-905. ⟨10.1016/j.clinbiomech.2005.05.017⟩. ⟨hal-00583066⟩
35 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More