E. Sims, D. Doughty, E. Macaulay, N. Royle, and C. Wraith, Stereotactically Delivered Cranial Radiation Therapy: A Ten-Year Experience of Linac-Based Radiosurgery in the UK, Clinical Oncology, vol.11, issue.5, pp.303-320, 1999.
DOI : 10.1053/clon.1999.9073

S. George, E. Kudhail, J. Perks, J. Plowman, and P. , Acute symptoms after gamma knife radiosurgery, J Neurosurg, vol.97, pp.631-634, 2002.

L. Leksell, The stereotactic method and radiosurgery of the brain, Acta Chir Scand, vol.102, pp.316-319, 1951.

D. Slatkin, P. Spanne, F. Dilmanian, and M. Sandborg, Microbeam radiation therapy, Medical Physics, vol.19, issue.6, pp.1395-1400, 1992.
DOI : 10.1118/1.596771

D. Slatkin, F. Dilmanian, and P. Spanne, Method for microbeam radiation therapy, 1994.

H. Curtis, The Interpretation of Microbeam Experiments for Manned Space Flight, Radiation Research Supplement, vol.7, pp.258-264, 1967.
DOI : 10.2307/3583719

H. Curtis, The Use of a Deuteron Microbeam for Simulating the Biological Effects of Heavy Cosmic-Ray Particles, Radiation Research Supplement, vol.7, pp.250-257, 1967.
DOI : 10.2307/3583718

W. Zeman, H. Curtis, and C. Baker, Histopathologic Effect of High-Energy-Particle Microbeams on the Visual Cortex of the Mouse Brain, Radiation Research, vol.15, issue.4, pp.496-514, 1961.
DOI : 10.2307/3571293

R. Serduc, Y. Van-de-looij, G. Francony, O. Verdonck, and B. Van-der-sanden, Characterization and quantification of cerebral edema induced by synchrotron x-ray microbeam radiation therapy, Physics in Medicine and Biology, vol.53, issue.5, pp.1153-1166, 2008.
DOI : 10.1088/0031-9155/53/5/001

URL : https://hal.archives-ouvertes.fr/inserm-00381404

R. Serduc, P. Verant, J. Vial, R. Farion, and L. Rocas, In vivo two-photon microscopy study of short-term effects of microbeam irradiation on normal mouse brain microvasculature, International Journal of Radiation Oncology*Biology*Physics, vol.64, issue.5, pp.1519-1527, 2006.
DOI : 10.1016/j.ijrobp.2005.11.047

URL : https://hal.archives-ouvertes.fr/inserm-00388979

L. Pena, Z. Fuks, and R. Kolesnick, Radiation-induced apoptosis of endothelial cells in the murine central nervous system: protection by fibroblast growth factor and sphingomyelinase deficiency, Cancer Res, vol.60, pp.321-327, 2000.

M. Fuss, F. Wenz, R. Scholdei, M. Essig, and J. Debus, Radiation-induced regional cerebral blood volume (rCBV) changes in normal brain and low-grade astrocytomas: quantification and time and dose-dependent occurrence, International Journal of Radiation Oncology*Biology*Physics, vol.48, issue.1, 2000.
DOI : 10.1016/S0360-3016(00)00590-3

E. Brä-uer-krisch, H. Requardt, P. Regnard, S. Corde, and E. Siegbahn, Exploiting geometrical irradiation possibilities in MRT application. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, pp.69-71, 2005.

O. David, I. Guillemain, S. Saillet, S. Reyt, and C. Deransart, Identifying Neural Drivers with Functional MRI: An Electrophysiological Validation, PLoS Biology, vol.54, issue.12, pp.2683-2697, 2008.
DOI : 10.1371/journal.pbio.0060315.sd002

URL : https://hal.archives-ouvertes.fr/inserm-00356680

P. Polack, I. Guillemain, E. Hu, C. Deransart, and A. Depaulis, Deep Layer Somatosensory Cortical Neurons Initiate Spike-and-Wave Discharges in a Genetic Model of Absence Seizures, Journal of Neuroscience, vol.27, issue.24, pp.6590-6599, 2007.
DOI : 10.1523/JNEUROSCI.0753-07.2007

URL : https://hal.archives-ouvertes.fr/inserm-00385581

W. Thomlinson, P. Berkvens, G. Berruyer, B. Bertrand, and H. Blattmann, Research at the European Synchrotron Radiation Facility medical beamline, Cell Mol Biol, vol.46, pp.1053-1063, 2000.

F. Salvat, J. Fernandez-varea, and J. Sempau, PENELOPE, a Code System for Monte Carlo Simulation of Electron and Photon Transport. OECD Nuclear Energy Agency Issy les-Moulineaux-France, 2006.

E. Siegbahn, E. Brauer-krisch, A. Bravin, H. Nettelbeck, and M. Lerch, MOSFET dosimetry with high spatial resolution in intense synchrotron-generated x-ray microbeams, Medical Physics, vol.28, issue.4, pp.1128-1137, 2009.
DOI : 10.1118/1.1374247

E. Siegbahn, J. Stepanek, E. Brä-uer-krisch, and A. Bravin, Determination of dosimetrical quantities used in microbeam radiation therapy (MRT) with Monte Carlo simulations, Medical Physics, vol.11, issue.9, pp.3248-3259, 2006.
DOI : 10.1118/1.2229422

R. Serduc, A. Bouchet, E. Bräuer-krisch, L. Duc, and G. , Microbeam radiation therapy parameters optimization for rat brain tumors palliation. Influence of the microbeam width at constant valley dose, Accepted Phys Med Biol, 2009.

F. Bouquet, C. Muller, and B. Salles, The Loss of γH2AX Signal is a Marker of DNA Double Strand Breaks Repair Only at Low Levels of DNA Damage, Cell Cycle, vol.5, issue.10, pp.1116-1122, 2006.
DOI : 10.4161/cc.5.10.2799

F. Dilmanian, Z. Zhong, T. Bacarian, H. Benveniste, and P. Romanelli, Interlaced x-ray microplanar beams: A radiosurgery approach with clinical potential, Proceedings of the National Academy of Sciences, vol.103, issue.25, pp.9709-9714, 2006.
DOI : 10.1073/pnas.0603567103

F. Dilmanian, J. Kalef-ezra, M. Petersen, G. Bozios, and J. Vosswinkel, Could X-ray microbeams inhibit angioplasty-induced restenosis in the rat carotid artery?, Cardiovascular Radiation Medicine, vol.4, issue.3, pp.139-145, 2003.
DOI : 10.1016/S1522-1865(03)00180-X

F. Dilmanian, Y. Qu, L. Feinendegen, L. Pena, and T. Bacarian, Tissue-sparing effect of x-ray microplanar beams particularly in the CNS: Is a bystander effect involved?, Experimental Hematology, vol.35, issue.4, pp.69-77, 2007.
DOI : 10.1016/j.exphem.2007.01.014

J. Laissue, H. Blattmann, D. Michiel, D. Slatkin, and N. Lyubimova, <title>Weanling piglet cerebellum: a surrogate for tolerance to MRT (microbeam radiation therapy) in pediatric neuro-oncology</title>, Penetrating Radiation Systems and Applications III, pp.65-73, 2001.
DOI : 10.1117/12.450774

J. Laissue, H. Blattmann, H. Wagner, M. Grotzer, and D. Slatkin, Prospects for microbeam radiation therapy of brain tumours in children to reduce neurological sequelae, Developmental Medicine & Child Neurology, vol.76, issue.8, pp.577-581, 2007.
DOI : 10.1111/j.1469-8749.2007.00577.x

J. Laissue, G. Geiser, P. Spanne, F. Dilmanian, and J. Gebbers, Neuropathology of ablation of rat gliosarcomas and contiguous brain tissues using a microplanar beam of synchrotron-wiggler-generated X rays, International Journal of Cancer, vol.14, issue.5, pp.654-660, 1998.
DOI : 10.1002/(SICI)1097-0215(19981123)78:5<654::AID-IJC21>3.0.CO;2-L

R. Serduc, T. Christen, J. Laissue, R. Farion, and A. Bouchet, study, Physics in Medicine and Biology, vol.53, issue.13, pp.3609-3622, 2008.
DOI : 10.1088/0031-9155/53/13/015

URL : https://hal.archives-ouvertes.fr/inserm-00381397

M. Reidy and S. Schwartz, Endothelial regeneration. III. Time course of intimal changes after small defined injury to rat aortic endothelium, Lab Invest, vol.44, pp.301-308, 1981.

S. Levegrun, H. Hof, M. Essig, W. Schlegel, and J. Debus, Radiation-induced changes of brain tissue after radiosurgery in patients with arteriovenous malformations: correlation with dose distribution parameters, International Journal of Radiation Oncology*Biology*Physics, vol.59, issue.3, pp.796-808, 2004.
DOI : 10.1016/j.ijrobp.2003.11.033

P. Sundgren, X. Fan, P. Weybright, R. Welsh, and R. Carlos, Differentiation of recurrent brain tumor versus radiation injury using diffusion tensor imaging in patients with new contrast-enhancing lesions, Magnetic Resonance Imaging, vol.24, issue.9, pp.1131-1142, 2006.
DOI : 10.1016/j.mri.2006.07.008

M. Van-vulpen, H. Kal, M. Taphoorn, and S. El-sharouni, Changes in blood-brain barrier permeability induced by radiotherapy: Implications for timing of chemotherapy? (Review), Oncology Reports, vol.9, pp.683-688, 2002.
DOI : 10.3892/or.9.4.683

D. Qin, G. Ou, H. Mo, Y. Song, and G. Kang, Improved efficacy of chemotherapy for glioblastoma by radiation-induced opening of blood-brain barrier: clinical results, International Journal of Radiation Oncology*Biology*Physics, vol.51, issue.4, pp.959-962, 2001.
DOI : 10.1016/S0360-3016(01)01735-7

S. Lonardi, A. Tosoni, and A. Brandes, Adjuvant chemotherapy in the treatment of high grade gliomas, Cancer Treatment Reviews, vol.31, issue.2, pp.79-89, 2005.
DOI : 10.1016/j.ctrv.2004.12.005

G. Barnett, M. Linskey, J. Adler, J. Cozzens, and W. Friedman, Stereotactic radiosurgery???an organized neurosurgery-sanctioned definition, Journal of Neurosurgery, vol.106, issue.1, pp.1-5, 2007.
DOI : 10.3171/jns.2007.106.1.1

D. Kondziolka, L. Lunsford, and J. Flickinger, THE APPLICATION OF STEREOTACTIC RADIOSURGERY TO DISORDERS OF THE BRAIN, Neurosurgery, vol.62, issue.Supplement 2, pp.707-719, 2008.
DOI : 10.1227/01.neu.0000316275.12962.0e

F. Bartolomei, M. Hayashi, M. Tamura, M. Rey, and C. Fischer, Long-term efficacy of gamma knife radiosurgery in mesial temporal lobe epilepsy, Neurology, vol.70, issue.19, pp.1658-1663, 2008.
DOI : 10.1212/01.wnl.0000294326.05118.d8

J. Regis, Y. Arkha, S. Yomo, F. Bartolomei, and J. Peragut, Radiosurgery for Drug-Resistant Epilepsies: State of the Art, Results, and Perspectives, Neurochirurgie, vol.54, pp.320-331, 2008.
DOI : 10.1007/978-1-4614-8363-2_58

B. Poncelet, V. Wedeen, R. Weisskoff, and M. Cohen, Brain parenchyma motion: measurement with cine echo-planar MR imaging., Radiology, vol.185, issue.3, pp.645-651, 1992.
DOI : 10.1148/radiology.185.3.1438740

D. Feinberg and A. Mark, Human brain motion and cerebrospinal fluid circulation demonstrated with MR velocity imaging., Radiology, vol.163, issue.3, pp.793-799, 1987.
DOI : 10.1148/radiology.163.3.3575734

D. Feinberg, Modern concepts of brain motion and cerebrospinal fluid flow., Radiology, vol.185, issue.3, pp.630-632, 1992.
DOI : 10.1148/radiology.185.3.1438734

D. Enzmann and N. Pelc, Brain motion: measurement with phase-contrast MR imaging., Radiology, vol.185, issue.3, pp.653-660, 1992.
DOI : 10.1148/radiology.185.3.1438741

C. Strik, U. Klose, M. Erb, H. Strik, and W. Grodd, Intracranial oscillations of cerebrospinal fluid and blood flows: Analysis with magnetic resonance imaging, Journal of Magnetic Resonance Imaging, vol.40, issue.3, pp.251-258, 2002.
DOI : 10.1002/jmri.10084

M. Soellinger, S. Ryf, P. Boesiger, and S. Kozerke, Assessment of human brain motion using CSPAMM, Journal of Magnetic Resonance Imaging, vol.3749, issue.4, pp.709-714, 2007.
DOI : 10.1002/jmri.20882

P. Pattany, I. Khamis, B. Bowen, K. Goodkin, and R. Weaver, Effects of physiologic human brain motion on proton spectroscopy: quantitative analysis and correction with cardiac gating, AJNR Am J Neuroradiol, vol.23, pp.225-230, 2002.

M. Renier, T. Brochard, C. Nemoz, and W. Thomlinson, A white-beam fastshutter for microbeam radiation therapy at the ESRF. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, pp.656-660, 2002.

T. Serizawa, Radiosurgery for metastatic brain tumors, International Journal of Clinical Oncology, vol.295, issue.Suppl1, pp.289-298, 2009.
DOI : 10.1007/s10147-009-0910-7

T. Serizawa, M. Yamamoto, O. Nagano, Y. Higuchi, and S. Matsuda, Gamma Knife surgery for metastatic brain tumors, J Neurosurg, vol.109, pp.118-121, 2008.

F. Dilmanian, T. Button, L. Duc, G. Zhong, N. Pena et al., Response of rat intracranial 9L gliosarcoma to microbeam radiation therapy, Neuro-Oncology, vol.4, issue.1, pp.26-38, 2002.
DOI : 10.1215/15228517-4-1-26

J. Laissue, Preclinical Microbeam Radiation Therapy (MRT): Concepts Experiments, 2003.

R. Serduc, Effets de la radiothérapie par microfaisceaux sur la microvascularisation saine et tumorale chez la souris, 2006.

C. Ohye and T. Shibazaki, Treatment of Functional Disorders with Gamma Knife Thalamotomy, Prog Neurol Surg, vol.22, pp.170-181, 2009.
DOI : 10.1159/000163416

B. Pollock, J. Flickinger, L. Lunsford, A. Maitz, and D. Kondziolka, Factors Associated with Successful Arteriovenous Malformation Radiosurgery, Neurosurgery, vol.42, issue.6, pp.1239-1244, 1998.
DOI : 10.1097/00006123-199806000-00020