Non-rigid registration method to assess reproducibility of breath-holding with ABC in lung cancer - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue International Journal of Radiation Oncology, Biology, Physics Année : 2005

Non-rigid registration method to assess reproducibility of breath-holding with ABC in lung cancer

Résumé

Purpose To study the interfraction reproducibility of breath-holding using active breath control (ABC), and to develop computerized tools to evaluate three-dimensional (3D) intrathoracic motion in each patient. Methods and materials Since June 2002, 11 patients with non–small-cell lung cancer enrolled in a Phase II trial have undergone four CT scans: one during free-breathing (reference) and three using ABC. Patients left the room between breath-hold scans. The patient's breath was held at the same predefined phase of the breathing cycle (about 70% of the vital capacity) using the ABC device, then patients received 3D-conformal radiotherapy. Automated computerized tools for breath-hold CT scans were developed to analyze lung and tumor interfraction residual motions with 3D nonrigid registration. Results All patients but one were safely treated with ABC for 7 weeks. For 6 patients, the lung volume differences were <5%. The mean 3D displacement inside the lungs was between 2.3 mm (SD 1.4) and 4 mm (SD 3.3), and the gross tumor volume residual motion was 0.9 mm (SD 0.4) to 5.9 mm (SD 0.7). The residual motion was slightly greater in the inferior part of the lung than the superior. For 2 patients, we detected volume changes >300 cm3 and displacements >10 mm, probably owing to atelectasia and emphysema. One patient was excluded, and two others had incomplete data sets. Conclusion Breath-holding with ABC was effective in 6 patients, and discrepancies were clinically accountable in 2. The proposed 3D nonrigid registration method allows for personalized evaluation of breath-holding reproducibility with ABC. It will be used to adapt the patient-specific internal margins.

Dates et versions

hal-00443454 , version 1 (29-12-2009)

Identifiants

Citer

David Sarrut, V. Boldea, M. Ayadi, J. N. Badel, C. Ginestet, et al.. Non-rigid registration method to assess reproducibility of breath-holding with ABC in lung cancer. International Journal of Radiation Oncology, Biology, Physics, 2005, 61 (2), pp.594--607. ⟨10.1016/j.ijrobp.2004.08.007⟩. ⟨hal-00443454⟩
121 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More