Control of the double pendulum optics suspension system of a 30 m triangular Fabry-Pérot cavity - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Review of Scientific Instruments Année : 2000

Control of the double pendulum optics suspension system of a 30 m triangular Fabry-Pérot cavity

Résumé

We present a technique for the control of a double pendulum suspension system used to carry the optical elements of a 30 m long Fabry-Pérot cavity, a prototype for the mode cleaner of the VIRGO experiment. The movement of the payload is sensed with a charge coupled device camera, and the feedback forces are applied to the intermediate stage of the suspension via coil-magnet systems. The control strategy is explained and the application of the system for the longitudinal locking of the cavity is demonstrated.
Fichier non déposé

Dates et versions

hal-00414588 , version 1 (09-09-2009)

Identifiants

Citer

M. Barsuglia, François Bondu, H. Heitmann, P. Heusse, C. N. Man, et al.. Control of the double pendulum optics suspension system of a 30 m triangular Fabry-Pérot cavity. Review of Scientific Instruments, 2000, 71, pp.2890-2894. ⟨10.1063/1.1150708⟩. ⟨hal-00414588⟩
45 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More