An inverse method for non invasive viscosity measurements - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue European Physical Journal: Applied Physics Année : 2007

An inverse method for non invasive viscosity measurements

Résumé

A procedure is presented which allows to compute in a non-invasive manner, blood viscosity through flow measurements obtained at a fixed vessel cross-section. The data set is made of measurements (artery radius and spatially discrete velocity profiles) performed at given time intervals for which the signal to noise ratio is typical of U.S. Doppler velocimetry in clinical situation. This identification approach is based on the minimization, through a backpropagation algorithm, of a cost function quantifying the distance between numerical data obtained through Navier-Stokes simulations and experimental measurements. Since this cost function implicitly depends on the value of viscosity used in numerical simulations, its minimization determines an effective viscosity which is shown to be robust to measurement errors and sampling time. Such an approach is shown to work in an in vitro experiment, and seems to be suitable for in vivo measurements of viscosity by the atraumatic techniques of Doppler echography.

Dates et versions

hal-00367793 , version 1 (12-03-2009)

Licence

Paternité

Identifiants

Citer

Jose-Maria Fullana, Nicolas Dispot, Patrice Flaud, Maurice Rossi. An inverse method for non invasive viscosity measurements. European Physical Journal: Applied Physics, 2007, 38 (1), pp.79-92. ⟨10.1051/epjap:2007049⟩. ⟨hal-00367793⟩