Experimental study of HBC fuses working at short and medium pre-arcing times - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Journal of Physics D: Applied Physics Année : 2008

Experimental study of HBC fuses working at short and medium pre-arcing times

Résumé

Pre-arcing stage is the first working step in High Breaking Capacity (HBC) fuse operation and affects the following step, namely the arcing step. We have performed realistic HBC fuse tests for short (< 10 ms) and medium (> 10 ms) pre-arcing times by varying the phase angle of the electrical fault (defined as the phase angle of the fault current once the supplied voltage is applied to the fuse) in the range from 0 to 160 deg., for two values of the power factor cos phi ~ 0.9 and cos phi ~ 0.1. Experimental values of the pre-arcing time and the arcing timeare given for tprearc/tarc ≲ 1 to ~ 4.2, and discussed from the energetic point of view by taking into account the inductive source term. The adiabatic assumption classically used in the modelling is also examined. The influence of the pre-arcing step on the arcing step is analysed by means of the Joule integral, the energy dissipated in the fuse, and the mass and length of the fulgurite.

Dates et versions

hal-00345477 , version 1 (09-12-2008)

Identifiants

Citer

William Bussiere, Pascal André, Thierry Latchimy, David Rochette, Gérard Velleaud, et al.. Experimental study of HBC fuses working at short and medium pre-arcing times. Journal of Physics D: Applied Physics, 2008, 41 (19), 13 pp. ⟨10.1088/0022-3727/41/19/195210⟩. ⟨hal-00345477⟩