Calibration of quasi-isotropic parallel kinematic Machines: Orthoglide - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2007

Calibration of quasi-isotropic parallel kinematic Machines: Orthoglide

Résumé

The paper proposes a novel approach for the geometrical model calibration of quasi-isotropic parallel kinematic mechanisms of the Orthoglide family. It is based on the observations of the manipulator leg parallelism during motions between the specific test postures and employs a low-cost measuring system composed of standard comparator indicators attached to the universal magnetic stands. They are sequentially used for measuring the deviation of the relevant leg location while the manipulator moves the TCP along the Cartesian axes. Using the measured differences, the developed algorithm estimates the joint offsets and the leg lengths that are treated as the most essential parameters. Validity of the proposed calibration technique is confirmed by the experimental results.
Fichier principal
Vignette du fichier
ICINCO_2007_final_cd.pdf (445.97 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00145161 , version 1 (08-05-2007)

Identifiants

Citer

Anatol Pashkevich, Roman Gomolitsky, Philippe Wenger, Damien Chablat. Calibration of quasi-isotropic parallel kinematic Machines: Orthoglide. May 2007, Angers, France. pp.1-8. ⟨hal-00145161⟩