Noncontact atomic force microscopy simulator with phase-locked-loop controlled frequency detection and excitation

Alexis Baratoff
  • Fonction : Auteur
  • PersonId : 831087
Dominique Schaer
  • Fonction : Auteur
Oliver Pfeiffer
  • Fonction : Auteur
  • PersonId : 831085
Ernst Meyer
  • Fonction : Auteur
  • PersonId : 831088

Résumé

A simulation of an atomic force microscope operating in the constant amplitude dynamic mode is described. The implementation mimics the electronics of a real setup including a digital phase-locked loop (PLL). The PLL is not only used as a very sensitive frequency detector, but also to generate the time-dependent phase shifted signal driving the cantilever. The optimum adjustments of individual functional blocks and their joint performance in typical experiments are determined in detail. Prior to testing the complete setup, the performances of the numerical PLL and of the amplitude controller were ascertained to be satisfactory compared to those of the real components. Attention is also focused on the issue of apparent dissipation, that is, of spurious variations in the driving amplitude caused by the nonlinear interaction occurring between the tip and the surface and by the finite response times of the various controllers. To do so, an estimate of the minimum dissipated energy that is detectable by the instrument upon operating conditions is given. This allows us to discuss the relevance of apparent dissipation that can be conditionally generated with the simulator in comparison to values reported experimentally. The analysis emphasizes that apparent dissipation can contribute to the measured dissipation up to 15% of the intrinsic dissipated energy of the cantilever interacting with the surface, but can be made negligible when properly adjusting the controllers, the PLL gains and the scan speed. It is inferred that the experimental values of dissipation usually reported in the literature cannot only originate in apparent dissipation, which favors the hypothesis of “physical” channels of dissipation.
Fichier principal
Vignette du fichier
manuscript_resubmission_prb_format.pdf (7.06 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00124764 , version 1 (30-01-2007)

Identifiants

Citer

Laurent Nony, Alexis Baratoff, Dominique Schaer, Oliver Pfeiffer, Adrian Wezel, et al.. Noncontact atomic force microscopy simulator with phase-locked-loop controlled frequency detection and excitation. Physical Review B: Condensed Matter and Materials Physics (1998-2015), 2006, 74, pp.235439. ⟨10.1103/PhysRevB.74.235439⟩. ⟨hal-00124764⟩
247 Consultations
392 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More