An improved PCA scheme for sensor FDI: Application to an air quality monitoring network - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Journal of Process Control Année : 2006

An improved PCA scheme for sensor FDI: Application to an air quality monitoring network

Résumé

In this paper a sensor fault detection and isolation procedure based on principal component analysis (PCA) is proposed to monitor an air quality monitoring network. The PCA model of the network is optimal with respect to a reconstruction error criterion. The sensor fault detection is carried out in various residual subspaces using a new detection index. For our application, this index improves the performance compared to classical detection index SPE. The reconstruction approach allows, on one hand, to isolate the faulty sensors and, on the other hand, to estimate the fault amplitudes.

Dates et versions

hal-00093739 , version 1 (13-09-2006)

Identifiants

Citer

Mohamed-Faouzi Harkat, Gilles Mourot, José Ragot. An improved PCA scheme for sensor FDI: Application to an air quality monitoring network. Journal of Process Control, 2006, 16 (6), pp.625-634. ⟨10.1016/j.jprocont.2005.09.007⟩. ⟨hal-00093739⟩
74 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More