Physico-Chemical Stability of Busulfan in Injectable Solutions in Various Administration Packages

Résumé

BACKGROUND AND OBJECTIVES: Busulfan is used as part of a conditioning regimen prior to hematopoietic stem cell transplantation for the treatment of certain cancers and immune deficiency syndromes. Due to its instability in aqueous preparations, busulfan for infusion is prepared from a concentrate and has a relatively short shelf life once prepared. The purpose of this study was to identify the most suitable storage container and temperature to maximize the shelf life of busulfan therapeutic infusions prepared from Busilvex(®). METHODS: Busilvex(®) 6 mg/mL was diluted to 0.55 mg/mL with 0.9 % NaCl and aliquots dispensed into polypropylene syringes, polyvinyl chloride bags, and glass bottles. Three storage temperatures were evaluated: 2-8 °C, 13-15 °C (thermostatically controlled chamber), and room temperature (20 ± 5 °C). At set time points, samples were analysed for busulfan content, using a high-performance liquid chromatography (HPLC) system with ultraviolet detection. The change in pH and osmolarity on storage was also determined, and solutions were inspected visually for formation of a precipitate or colour change. To determine the contribution of precipitation to loss of busulfan content on storage, samples from one time series were treated with the solvent dimethylacetamide prior to HPLC separation and quantitation of busulfan. RESULTS: The results of the active substance content monitoring study over a 48-h period demonstrate that busulfan solution is stable at a 5 % threshold, at 2-8 °C for 16 h in syringes, 14 h in glass bottles, and 6 h in bags. In addition, the period of stability decreases as the temperature increases (4 h at 20 ± 5 °C). The solution is considered to be stable, subject to precipitation liable to be observed regardless of the temperature. CONCLUSION: The best stability was observed for busulfan solutions placed at 2-8 °C in syringes. This study demonstrated that precipitation, in addition to hydrolysis, has a significant influence on the busulfan content.
Fichier principal
Vignette du fichier
40268_2013_Article_3.pdf (526.78 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-01514079 , version 1 (08-06-2021)

Identifiants

Citer

Mélanie Houot, Vianney Poinsignon, Lionel Mercier, Cyril Valade, Romain Desmaris, et al.. Physico-Chemical Stability of Busulfan in Injectable Solutions in Various Administration Packages. Drugs in R&D, 2013, 13 (1), pp.87 - 94. ⟨10.1007/s40268-013-0003-y⟩. ⟨hal-01514079⟩
78 Consultations
64 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More