An automated myocardial segmentation in cardiac MRI.
El Berbari R., Bloch I., Redheuil A. B., Angelini E., Mousseaux E., Frouin F., Herment A.
Conference proceedings : Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 1 (2007) 4508-11 - http://www.hal.inserm.fr/inserm-00194347
An automated myocardial segmentation in cardiac MRI.
Racha El Berbari ( ) 1, 2, Isabelle Bloch 2, Alban B. Redheuil 1, 3, Elsa Angelini 2, Elie Mousseaux 1, 3, Frédérique Frouin 1, Alain Herment 1
1 :  Laboratoire d'Imagerie Fonctionnelle (LIF)
http://www.imed.jussieu.fr/
INSERM : U678 – IFR14 – IFR49 – Université Pierre et Marie Curie (UPMC) - Paris VI
Faculte de Medecine Pitie-Salpetriere 91, Boulevard de L'Hopital 75634 PARIS CEDEX 13
France
2 :  Laboratoire Traitement et Communication de l'Information [Paris] (LTCI)
http://www.ltci.telecom-paristech.fr/
Télécom ParisTech – CNRS : UMR5141
CNRS LTCI Télécom ParisTech 46 rue Barrault F-75634 Paris Cedex 13
France
3 :  Service de radiologie cardio-vasculaire
Assistance publique - Hôpitaux de Paris (AP-HP) – Hôpital européen Georges Pompidou – Université Paris V - Paris Descartes
20 rue Leblanc, Cedex 15, 75908 Paris, France
France
In this paper we present an automatic approach to segment Cardiac Magnetic Resonance (CMR) images. A preprocessing step that consists in filtering the image using connected operators (area opening and closing filters) is applied in order to homogenize the cavity and solve the problems due to the papillary muscles. Thereby the GVF snake algorithm is applied with one point clicked in the cavity as initialization and an optimized tuning of parameters for the endocardial contour extraction. The epicardial border is then obtained using the endocardium as initialization. The performance of the proposed method was assessed by experimentation on thirtynine CMR images. A high agreement between manual and automatic contours was obtained with correlation scores of 0.96 for the endocardium and 0.90 for the epicardium. Overlapping percentage, mean and maximum distances between the two contours show a good performance of the method.
Articles dans des revues avec comité de lecture
Sciences du Vivant/Médecine humaine et pathologie/Cardiologie et système cardiovasculaire
Sciences du Vivant/Ingénierie biomédicale
Anglais
1557-170X

Conference proceedings : Annual International Conference of the IEEE Engineering in Medicine and Biology Society. (Conf Proc IEEE Eng Med Biol Soc)
Publisher Institute of Electrical and Electronics Engineers (IEEE)
ISSN 1557-170X 
internationale
2007
1
4508-11

Liste des fichiers attachés à ce document : 
PDF
04353341.pdf(358.8 KB)