| HAL: hal-00674678, version 1 |
| Detailed view | Export this paper |
|
|
| European Power Electronic Conference 2003, TOULOUSE : France (2003) |
|
|
|
|
| Energy Modeling of a Lead-Acid Battery within Hybrid Wind/Photovoltaic Systems |
|
|
| Olivier Gergaud 1Gaël Robin 1 |
|
|
| (2003-09) |
|
|
| Within the scope of full-scale energy modeling of a hybrid wind / photovoltaic system coupled to the network, our focus herein lies in a battery set-up that makes use of the CIEMAT model. The implementation and energy-based analysis of this model are conducted with emphasis on the continuous estimation of battery capacity. A measurement vs. model results comparison is then performed under actual operating conditions. |
|
|
|
|
|
|
|
|
|
|
| 1: | Systèmes et Applications des Technologies de l'Information et de l'Energie (SATIE) |
| CNRS : UMR8029 – École normale supérieure de Cachan - ENS Cachan | |
|
|
|
|
|
|
|
|
| SATIE-SETE |
|
|
|
|
| Subject | : | Engineering Sciences/Electric power |
|
|
| Lead Acid Battery – Battery management – Modelling – Renewable energy systems |
|
|
| Attached file list to this document: | |||||
|
|
|
| hal-00674678, version 1 | |
| http://hal.archives-ouvertes.fr/hal-00674678 | |
| oai:hal.archives-ouvertes.fr:hal-00674678 | |
| From: Bernard Multon | |
| Submitted on: Monday, 27 February 2012 20:50:27 | |
| Updated on: Tuesday, 28 February 2012 10:12:07 | |