Methods to suppress polarization in chlorine compensated cadmium telluride detectors - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Revue de Physique Appliquée Année : 1977

Methods to suppress polarization in chlorine compensated cadmium telluride detectors

Résumé

In a first part of this paper, the different models of polarization developped in the literature are critically analyzed. Then, the origin of the responsible center, its location within the bandgap and its concentration is investigated and discussed. Finally, three methods to suppress this effect are presented, mainly surface oxidation in perhydrol of the etched sample prior to the metal deposition, evaporation of a thin SiOx layer or ion implantation.
Fichier principal
Vignette du fichier
ajp-rphysap_1977_12_2_335_0.pdf (622.13 Ko) Télécharger le fichier
Origine : Accord explicite pour ce dépôt

Dates et versions

jpa-00244168 , version 1 (04-02-2008)

Identifiants

Citer

P. Siffert, M. Hage-Ali, R. Stuck, A. Cornet. Methods to suppress polarization in chlorine compensated cadmium telluride detectors. International Symposium On Cadmium Telluride: Physical Properties And Applications 2, 1976, Strasbourg, France. pp.335-338, ⟨10.1051/rphysap:01977001202033500⟩. ⟨jpa-00244168⟩