When a living tissue is subjected to cyclic stretching, the stress-strain curves show a shift down with the increase in the number of cycles until stabilization. This phenomenon is referred to in the literature as a preconditioning and is performed to obtain repeatable and predictable measurements. Preconditioning has been routinely performed in skin tissue tests; however, its effects on the mechanical properties of the material such as viscoelastic response, tangent modulus, sensitivity to strain rate, the stress relaxation rate, etc….remain unclear. In addition, various physical interpretations of this phenomenon have been proposed and there is no general agreement on its origin at the microscopic or mesoscopic scales. The purpose of this study was to investigate the effect of the cyclical stretching and the stress-relaxation tests on the mechanical properties of the porcine skin. Cyclic uniaxial tensile tests at large and constant strain were performed on different skin samples. The change in the reaction force, and skin's tangent modulus as a function of the number of cycles, as well as the strain rate effect on the mechanical behavior of skin samples after cycling were investigated. Stress-relaxation tests were also performed on skin samples. The change in the reaction force as a function of relaxation time and the strain rate effect on the mechanical behavior of skin samples after the stress-relaxation were investigated. The mechanical behavior of a skin sample under stress-relaxation test was modeled using a combination of hyperelasticity and viscoelasticity. Overall, the results showed that the mechanical behavior of the skin was strongly influenced by cycling and stress relaxation tests. Indeed, it was observed that the skin's resistance decreased by about half for two hours of cycling; the tangent modulus degraded by nearly 30% and skin samples became insensitive to the strain rates and accumulated progressively an inelastic deformation over time during cycling. Finally, the hysteresis loops became very narrow at the end of cycling and after relaxation process.
Fichier principal
Vignette du fichier
Journal of the Mechanical Behavior of Biomedical Materials.pdf (903.26 Ko) Télécharger le fichier
Origine : Publication financée par une institution
Loading...

Dates et versions

hal-01687525 , version 1 (18-01-2018)

Identifiants

Citer

Djamel Remache, Michael Caliez, Michel Gratton, Serge dos Santos. The effects of cyclic tensile and stress-relaxation tests on porcine skin. Journal of the mechanical behavior of biomedical materials, 2018, 77, pp.242-249. ⟨10.1016/j.jmbbm.2017.09.009⟩. ⟨hal-01687525⟩
144 Consultations
1134 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More