Comparison of different methods of incorporating respiratory motion for lung cancer tumor volume delineation on PET images: a simulation study.

Résumé

The interest of PET complementary information for the delineation of the target volume in radiotherapy of lung cancer is increasing. However, respiratory motion requires the determination of a functional internal target volume (ITV) on PET images for which several strategies have been proposed. The purpose of this study was the comparison of these strategies for taking into account respiratory motion and deriving the ITV: (1) adding fixed margins to the volume defined on a single binned image, (2) segmenting a motion averaged image and (3) considering the union of volumes delineated on binned frames. For this third strategy, binned frames were either non-corrected for motion, or corrected using two different methods: elastic registration or super resolution. The strategies' performances were assessed on realistic simulated datasets combining the NCAT phantom with a PET Philips GEMINI scanner model in GATE, and containing various configurations of tumor to background contrast, with both regular and irregular respiratory motion (with a range of motion amplitudes). The obtained ITVs' sensitivity (SE) and positive predictive value (PVE) with respect to the known true ITV were significantly higher (from 0.8 to 0.95) than all other techniques when using binned frames corrected for motion, independently of motion regularity, amplitude, or tumor to background contrast. Although the absolute difference was small and not always significant, images corrected using super resolution led to systematically better results than using elastic registration. The worst results were obtained when using the motion averaged image for SE (around 0.5-0.6) and using the margins added to a single frame for PPV (0.6-0.7), respectively. The best strategy to account for breathing motion for tumor ITV delineation in radiotherapy planning is to rely on the use of the union of volumes delineated on super resolution-corrected binned images.
Fichier principal
Vignette du fichier
PMB2012_ITV.pdf (754.27 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00749010 , version 1 (06-11-2012)

Identifiants

Citer

Mathieu Hatt, Amandine Le Maitre, Daphné Wallach, Hadi Fayad, Dimitris Visvikis. Comparison of different methods of incorporating respiratory motion for lung cancer tumor volume delineation on PET images: a simulation study.. Physics in Medicine and Biology, 2012, 57 (22), pp.7409-30. ⟨10.1088/0031-9155/57/22/7409⟩. ⟨hal-00749010⟩
132 Consultations
203 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More