Large differences between test strategies for the detection of anti- antibodies are revealed by comparing eight ELISAs and five immunoblots - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue European Journal of Clinical Microbiology and Infectious Diseases Année : 2011

Large differences between test strategies for the detection of anti- antibodies are revealed by comparing eight ELISAs and five immunoblots

Résumé

We investigated the influence of assay choice on the results in a two-tier testing algorithm for the detection of anti- antibodies. Eighty-nine serum samples from clinically well-defined patients were tested in eight different enzyme-linked immunosorbent assay (ELISA) systems based on whole-cell antigens, whole-cell antigens supplemented with VlsE and assays using exclusively recombinant proteins. A subset of samples was tested in five immunoblots: one whole-cell blot, one whole-cell blot supplemented with VlsE and three recombinant blots. The number of IgM- and/or IgG-positive ELISA results in the group of patients suspected of infection ranged from 34 to 59%. The percentage of positives in cross-reactivity controls ranged from 0 to 38%. Comparison of immunoblots yielded large differences in inter-test agreement and showed, at best, a moderate agreement between tests. Remarkably, some immunoblots gave positive results in samples that had been tested negative by all eight ELISAs. The percentage of positive blots following a positive ELISA result depended heavily on the choice of ELISA-immunoblot combination. We conclude that the assays used to detect anti- antibodies have widely divergent sensitivity and specificity. The choice of ELISA-immunoblot combination severely influences the number of positive results, making the exchange of test results between laboratories with different methodologies hazardous.

Mots clés

Fichier principal
Vignette du fichier
PEER_stage2_10.1007%2Fs10096-011-1157-6.pdf (172.83 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00663398 , version 1 (27-01-2012)

Identifiants

Citer

C. W. Ang, D. W. Notermans, M. Hommes, A. M. Simoons-Smit, T. Herremans. Large differences between test strategies for the detection of anti- antibodies are revealed by comparing eight ELISAs and five immunoblots. European Journal of Clinical Microbiology and Infectious Diseases, 2011, 30 (8), pp.1027-1032. ⟨10.1007/s10096-011-1157-6⟩. ⟨hal-00663398⟩