Impact of Electronic Conditioning on the Noise Performance of a Two-Port Network Giant MagnetoImpedance Magnetometer - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue IEEE Sensors Journal Année : 2010

Impact of Electronic Conditioning on the Noise Performance of a Two-Port Network Giant MagnetoImpedance Magnetometer

Résumé

The performance of giant magneto-impedance (GMI)-based magnetometers is currently limited by the noise due to the electronic conditioning circuitry. We propose a simple model of this noise for a GMI sensor using a synchronous detection scheme. The GMI sensing element consists of a thin pick-up coil wound around a Co-rich amorphous micro-wire. It is fully described by a two port network model and associated impedance matrix. Noise and sensitivity behavior are studied for the four measuring configurations, corresponding to four terms of the impedance matrix. The model yields a good description of experimental data from noise measurements. The magnetic noise spectral density is dominated either by the excitation or detection stages, depending upon whether the excitation currents are high or low. The nontrivial noise behavior exhibited by each configuration leads to better understanding of the noise limitations of GMI magnetometers. The configuration in which the signal at the coil terminals is measured (often called offdiagonal) is the most efficient in decreasing the equivalent output magnetic noise spectral density. (c) 2010 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other users, including reprinting/ republishing this material for advertising or promotional purposes, creating new collective works for resale or redistribution to servers or lists, or reuse of any copyrighted components of this work in other works.

Domaines

Electronique
Fichier principal
Vignette du fichier
Manuscript.pdf (1.5 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00635846 , version 1 (26-10-2011)

Identifiants

Citer

Basile Dufay, Sébastien Saez, Christophe Dolabdjian, Arthur Yelon, David Ménard. Impact of Electronic Conditioning on the Noise Performance of a Two-Port Network Giant MagnetoImpedance Magnetometer. IEEE Sensors Journal, 2010, 11 (6), pp.1317 - 1324. ⟨10.1109/JSEN.2010.2084996⟩. ⟨hal-00635846⟩
360 Consultations
267 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More