Time-resolved tomographic measurements of temperatures in a thermal plasma jet
Résumé
Temperatures in a thermal plasma jet were measured using an experimental set-up providing time-resolved scans of plasma optical radiation near 650 nm from 4 directions. The acquired data were used for reconstructions of time-resolved temperature distributions in measurement planes perpendicular to the plasma jet axis. The plasma torch was fed by the d.c. power source with a substantial ripple voltage modulation which leads to significant differences between the temperature distributions according to the actual phase of the arc current.
Fichier principal
PEER_stage2_10.1088%2F0022-3727%2F43%2F5%2F055202.pdf (334.33 Ko)
Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)