The expected background spectrum in NaI dark matter detectors and the DAMA result
Résumé
Detailed Monte Carlo simulations of the expected radioactive background rates and spectra in NaI crystals are presented. The obtained spectra are then compared to those measured in the DAMA/NaI and DAMA/LIBRA experiments.The simulations can be made consistent with the measured DAMA spectrum only by assuming higher than reported concentrations of some isotopes and even so leave very little room for the dark matter signal. We conclude that any interpretation of the annual modulation of the event rate observed by DAMA as a dark matter signal, should include full consideration of the background spectrum. This would significantly restrict the range of dark matter models capable of explaining the modulation effect.
Fichier principal
PEER_stage2_10.1016%2Fj.astropartphys.2009.12.003.pdf (693.21 Ko)
Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)