Corrosion Diagnosis of a Ship Mock-Up From Near Electric-Field Measurements - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue IEEE Transactions on Magnetics Année : 2010

Corrosion Diagnosis of a Ship Mock-Up From Near Electric-Field Measurements

Résumé

We present here an original application linking an electrochemical phenomenon and the computational aspect of electromagnetic fields to provide a corrosion diagnosis of a protected underwater steel structure. This is done with the pairing of a boundary element method and the resolution of an inverse problem. After a defined operating time, it is mandatory to check an underwater steel structure. Sadly, current examinations techniques require immobilizing the structure for a long time and are less efficient. The purpose of this paper is to replace this checking by a series of close electrical measurements in the conducting water which provides a corrosion diagnosis of the structure. The new method introduced ensures great time-savings but also an accuracy never reached before. This paper presents this numerical method and its checking through real electrical measurements on a frigate mock-up.
Fichier principal
Vignette du fichier
05512963.pdf (637.97 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-00523577 , version 1 (05-10-2010)

Identifiants

Citer

Arnaud Guibert, Jean-Louis Coulomb, Olivier Chadebec, Corinne Rannou. Corrosion Diagnosis of a Ship Mock-Up From Near Electric-Field Measurements. IEEE Transactions on Magnetics, 2010, 46 (8), pp.3205-3208. ⟨10.1109/TMAG.2010.2048098⟩. ⟨hal-00523577⟩
222 Consultations
250 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More