Preconcentration Modeling for the Optimization of a Micro Gas Preconcentrator Applied to Environmental Monitoring - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Procedia Chemistry Année : 2009

Preconcentration Modeling for the Optimization of a Micro Gas Preconcentrator Applied to Environmental Monitoring

Résumé

This paper presents the complete modeling of the preconcentration cycle for the optimization of a Micro Gas Preconcentrator applied to atmospheric pollution monitoring. The particularity of this modeling is based on the fact that it includes all equations governing not only the adsorption and desorption phenomena but also the detection phase. Two different approaches based on kinetic equations were used to illustrate the behavior of the Micro Gas Preconcentrator for given experimental conditions. The need of a high adsorption flow and heating rate, a low desorption flow and detection volume is demonstrated through this paper.
Fichier principal
Vignette du fichier
PC-EHMC-1-1.pdf (189.11 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00451764 , version 1 (30-01-2010)

Identifiants

Citer

El Hadji Malick Camara, Philippe Breuil, Christophe Pijolat. Preconcentration Modeling for the Optimization of a Micro Gas Preconcentrator Applied to Environmental Monitoring. Procedia Chemistry, 2009, 1 (1), pp.662-665. ⟨10.1016/j.proche.2009.07.165⟩. ⟨hal-00451764⟩